When importing a configuration file into a new SPS appliance, the following error occurs:
Error validating XML with schema
schema='/opt/scb/share/xml/validator/xmldb/scb.xsd', error='Element 'scb',attribute 'maor_version': The value 'scb66' does not match the fixed value contraint 'scb62'. Element 'scb', attribute 'revision': The value '2' does not match the fixed value constraint '4'.
In this scenario, the configuration file was exported from a newer version (6.6) and being imported into an older version (6.2) causing a mismatch for some of the attributes that are included in the newer version configuration file.
Configuration export file was from a new SPS version and had mismatched attributes when attempting to import into an older SPS version
RESOLUTION:
- Upgrade the new target SPS appliance to match the version of the original SPS appliance where the export file was taken from then import the configuration file.
© 2024 One Identity LLC. ALL RIGHTS RESERVED. Feedback Conditions d’utilisation Confidentialité Cookie Preference Center