When using WEC (Windows Event Collector) the connection cannot be established and the following error(s) are seen:
<f:WSManFault xmlns:f="http://schemas.microsoft.com/wbem/wsman/1/wsmanfault" Code="995" Machine="example.ad.domain.com"><f:Message>WS-Management cannot process the request. The operation failed because of an HTTP error. The HTTP error (2148074279) is: An unknown error occurred while processing the certificate. . </f:Message></f:WSManFault>.
995 (HTTP error 12186): The "Network Service" does not have permission to read the client certificate.
Please rename and move the Network Service profile.
Once done, please reboot the server. The Network Service profile will re-create itself and should begin to function with WEC after the reboot.