A synchronization project collects all the information required for synchronizing the One Identity Manager database with a target system. Connection data for target systems, schema types and properties, mapping, and synchronization workflows all belong to this.
Make the following information available for setting up a synchronization project for synchronizing with the generic database connector.
Table 5: Information required for setting up a synchronization project
Synchronization server |
All One Identity Manager Service actions are run against the target system environment on the synchronization server. Data entries required for synchronization and administration with the One Identity Manager database are processed by the synchronization server.
Installed components:
The synchronization server must be declared as a Job server in One Identity Manager. The Job server name is required.
For more information, see Setting up the synchronization server. |
Remote connection server |
To configure synchronization with a target system, One Identity Manager must load the data from the target system. One Identity Manager communicates directly with the target system to do this. Sometimes direct access from the workstation, on which the Synchronization Editor is installed, is not possible. For example, because of the firewall configuration or the workstation does not fulfill the necessary hardware and software requirements.
The remote connection server and the workstation must be in the same Active Directory domain.
Remote connection server configuration:
-
One Identity Manager Service is started
-
RemoteConnectPlugin is installed
-
SAP HANA data provider for ADO.NET is installed
The remote connection server must be declared as a Job server in One Identity Manager. The Job server name is required.
For more detailed information about setting up a remote connection, see the One Identity Manager Target System Synchronization Reference Guide. |
Synchronization workflow |
Set the Data import option in the synchronization step if synchronization data is imported from a secondary system.
For more detailed information about synchronizing user data with different systems, see the One Identity Manager Target System Synchronization Reference Guide. |
Base object |
You cannot normally specify a base object for synchronizing with database connectors. In this case, assignment of one base table and the synchronization server is sufficient.
-
Select the table from the Base table menu in which to load the objects. The base table can be used to defined downstream processes for synchronization. For more information about downstream processes, see the One Identity Manager Target System Synchronization Reference Guide.
-
The Synchronization servers menu displays all Job servers for which the Generic database connector server function is set. |
Variable set |
If you implement specialized variable sets, ensure that the start up configuration and the base object use the same variable set. |
To configure synchronization with the generic database connector
-
Create a new synchronization project.
-
Add mappings. Define property mapping rules and object matching rules.
-
Create synchronization workflows.
-
Create a start up configuration.
-
Define the synchronization scope.
-
Specify the base object of the synchronization.
-
Specify the extent of the synchronization log.
-
Run a consistency check.
-
Activate the synchronization project.
-
Save the new synchronization project in the database.
Detailed information about this topic
There is a wizard to assist you with setting up a synchronization project. This wizard takes you through all the steps you need to set up initial synchronization with a target system. Click Next once you have entered all the data for a step.
NOTE: The following sequence describes how to configure a synchronization project if the Synchronization Editor is both:
If you run the project wizard in expert mode or directly from the Synchronization Editor, additional configuration settings can be made. Follow the project wizard instructions through these steps.
Prerequisite
To set up a synchronization project
-
Start the Launchpad and log in on the One Identity Manager database.
NOTE: If synchronization is run by an application server, connect the database through the application server.
-
Select the Generic Database Connector and click Run.
This starts the Synchronization Editor's project wizard.
-
On the System access page, specify how One Identity Manager can access the target system.
-
If access is possible from the workstation on which you started the Synchronization Editor, do not change any settings.
-
If access is not possible from the workstation on which you started the Synchronization Editor, you can set up a remote connection.
Enable the Connect using remote connection server option and select the server to be used for the connection under Job server.
-
On the Select database system page, select the database system to which you want to connect.
-
Configure the system connection.
For more information, see Connecting a system to an SAP HANA database.
-
On the Save configuration page, you can save the current configuration as a template. When you reconnect to a database system of the same type, you can use this configuration as a template.
-
You can save the connection data on the last page of the system connection wizard.
-
Set the Save connection locally option to save the connection data. This can be reused when you set up other synchronization projects.
-
Click Finish, to end the system connection wizard and return to the project wizard.
-
On the One Identity Manager Connection tab, test the data for connecting to the One Identity Manager database. The data is loaded from the connected database. Reenter the password.
NOTE:
-
If you use an unencrypted One Identity Manager database and have not yet saved any synchronization projects to the database, you need to enter all connection data again.
-
This page is not shown if a synchronization project already exists.
-
The wizard loads the target system schema. This may take a few minutes depending on the type of target system access and the size of the target system.
-
On the Select project template page, select a project template to use for setting up the synchronization configuration.
NOTE: The generic database connector does not provide a default project template for setting up synchronization. If you have created your own project template, you can select it to configure the synchronization project. Otherwise, select Create blank project.
-
Enter the general setting for the synchronization project under General.
Table 6: General properties of the synchronization project
Display name |
Display name for the synchronization project. |
Description |
Text field for additional explanation. |
-
To close the project wizard, click Finish.
-
Save the synchronization project in the database.
Table 7: Required information for connecting the system
Server |
Name of the server on which the database server is installed. The fully qualified server name or the IP address may be given. |
User account and password |
User account and password used by the generic database connector to log in to the external database. Make a user account available with sufficient permissions.
For more information, see Error connecting with the target system. |
Database |
Name of the external database to be synchronized. |
Installed SAP HANA provider |
Provider that connects to the SAP HANA database. |
To configure the connection to an SAP HANA database:
-
On the Database connection page, enter the connection parameters. Select the SAP HANA provider and enter all the parameters required by the generic database connector to create a connection with the selected database system.
The database system connection is tested the moment you click Next.
-
On the Describe the database page, enter a display name and a unique identifier for the database connection.
-
Database display name: Display name of the database for displaying in the One Identity Manager tools.
-
System identifier: Unique system identifier.
IMPORTANT: The system identifier of the database must be unique. These identifiers help to differentiate between the databases. To prevent incorrect behavior and loss of data ensure that the system identifiers are unique within the One Identity Manager environment.
-
System category: Category for further differentiation of system types. A maximum of 16 characters, consisting of numbers and letters, are permitted for the identifier.
Connections with the generic database connector are usually stored with the DB system type. The system category allows one more classification into subtypes. This allows different database connections with differing content to be distinguished from one another.
Example:
Connection 1: type=DB, subtype=Rights
Connection 2: type=DB, subtype=PersonImport
-
On the Load configuration page, you can enter a file from which the connection configuration can be loaded. This data is used in subsequent steps in the connection wizard and can be modified there.
-
On the Time zone selection page, select the time zone for the time zone data in the database. The time zone is required to convert the time saved in the database into the local time. The local time is displayed in One Identity Manager tools.
-
On the Initializing page, you can specify additional connection settings. Write a script in the database syntax to specify number and date formats, language, and data sort order, for example. This script is then run every time you connect the system.
-
On the Initialization page, you can write a script that is run each time a connection is established. For example, connection settings for data sort order, language, or date format can be defined by the script.
-
On the Select partial schemas page, you can reduce the database schema by selecting partial schemas. If the database contains several schema, specify here, which schemas are loaded into the synchronization project.
-
The database schema is loaded on the Schema detection page. during which One Identity Manager tries to identify a known schema.
If the schema is loaded successfully, the next step in the sequence can be carried out.
-
On the Extend key information page, specify columns for each table to be used as unique keys for identifying objects.
Table 8: Defining unique keys
Hide unconfigured tables |
Specifies whether tables are hidden if no settings have been changed. |
Schema |
Tables without a unique key. |
Column is key |
Specifies whether the column contains a unique key. |
Column group |
Button for editing column groups. Create a column group, if a unique key can only be made of a combination of more than one column.
-
To create a column group, click Add.
-
To edit or remove an existing column group, click Edit or remove. |
Table 9: Column group properties
Key name |
Column group identifier. Permitted characters are letters and underscore. A virtual schema property is formed from the column group called vrtColumnGroup<column group>. |
Columns |
Columns included in the column group. Mark all the columns that together make up the unique key.
NOTE: Columns of type Char are not supported. |
-
On the Define data relations page, you can enter information about object relations.
Table 10: Defining column relations
Hide unconfigured tables |
Specifies whether tables are hidden if no settings have been changed. |
Schema |
Database schema tables. |
Target(s) |
Columns to which the reference refers. Enter the table and column name in the following syntax:
<schema>.]<table name>.<column name>
If a reference points to several column, enter the targets in a comma delimited list. The target columns must be labeled as key columns.
TIP: You can copy the column name of a referenced column using the Copy fully qualified column names item in the context menu and add this as a target. |
Referential integrity enabled |
Specifies whether the referential integrity of the data in the target table has been tested. |
-
On the Complete schema page, you can enter additional schema information.
Table 11: Additional schema information
Hide unconfigured tables |
Specifies whether tables are hidden if no settings have been changed. |
Schema |
Tables and schemas of the database schema. |
Display value |
Column used in the display pattern.
|
Preferred key |
Specifies whether the column is primarily used for object identification. A preferred key can defined, if a table has more than one unique key. Only columns with the String data type can be selected. |
Contains sensitive data |
Specifies whether the column contains sensitive data. |
Revision counter |
Specifies whether the column contains the revision counter. The data in this column form the comparison value for revision filtering. |
Sort criteria for hierarchies |
Specifies whether the value in this column maps the path in an object hierarchy. If this table’s objects are sorted by this column, it results in a list sorted in hierarchical order. This makes it possible to resolve object dependencies. Only one column per table can be marked as a sort criterion. An example is the CanonicalName column. |
Scope reference |
Specifies whether the column can be used to form the reference scope. Only one column per schema type can be labeled as the reference scope. |
Auto fill behavior |
Specifies whether the values entered in the column are identified automatically. |
Enable compatible null handling |
Specifies whether a null value in the column is converted to an empty string. |
Table 12: Table properties
Display template |
Display pattern with which the objects in the Synchronization Editor are displayed. The display pattern is, for example, used in error messages or test result from object matching rules. The display pattern is, for example, used in error messages or in the test results from object matching rules. Enter a display table for each display pattern.
|
-
On the Define data operations page, you can specify special operations for changing data in the external database. This is only required, if the default operations INSERT, UPDATE, and DELETE cannot be used in the external database system.
|
WARNING: A good knowledge of programming is required to implement data operations. Errors in this implementation can lead to loss of data. |
To define a data operation
-
Select a table and mark the operation you want to define.
-
Select a strategy.
-
Enter the data operation you want to run in the Settings input field.
Table 13: Defining data operations
Hide unconfigured tables |
Specifies whether tables are hidden if no settings have been changed. |
Table/operation |
Tables for which the data operations are to be defined. |
Strategy |
Strategy with which the data operation is created and run. A simple procedure can be called for a data operation or a script can be run. Select the strategy you want use to define the data operation.
-
Pattern based: Simple procedure call that runs the operation.
NOTE: If column names are referenced that contain special characters, replace the special characters with an underscore (_). Special characters are everything apart from letters, numbers and underscore.
-
Script based: Script that performs a complex data operation.
You can use custom code snippets in the script. The code snippets must contain a keyword element with the DML keyword. For more detailed information about support for writing scripts, see the One Identity Manager Target System Synchronization Reference Guide.
|
Required columns |
List of required key columns in a script-based data operation. The columns must be entered if they are not part of the display name. |
Settings |
Define the data operation that is to be run when objects are added, updated, or deleted. Enter the procedure call or create a script depending on the selected strategy.
Example of a pattern-based data operation:
exec CreateUser('%Uid%','%FirstName%','%LastName%')
It has an advanced edit mode which provides additional actions. For more information about support for creating scripts, see the One Identity Manager Target System Synchronization Reference Guide. |
-
The Extend target system schema page opens if you enable the Fill in system description completely option on the Load schema page or make settings on the Define data operations page. You can add virtual schema properties to the target system schema here. Use the virtual schema properties to provide additional data for your own DML handling.
Table 14: Virtual schema properties
Hide unconfigured tables |
Specifies whether tables are hidden if no settings have been changed. |
Schema |
Tables in the target system schema for which virtual schema properties can be added or exist already. |
Virtual schema properties |
Buttons for editing virtual schema properties
|
Data type |
Data type of the schema property |
Multivalue |
Specifies whether the schema property has multiple values |
Required field |
Specifies whether the schema property is a mandatory property |
Secret |
Specifies whether the schema property value may be displayed in the Synchronization Editor or in logs, reports, and messages. If this option is set, the value is not displayed. |
To edit or delete a virtual schema property
-
In the Schema column, open the node of the table with the schema properties that you want to edit or delete.
-
Click Edit or remove.
-
Edit the properties of the virtual schema property.
- OR -
Click Delete.
Related topics
All the schema data (schema types and schema properties) of the target system schema and the One Identity Manager schema are available when you are editing a synchronization project. Only a part of this data is really needed for configuring synchronization. If a synchronization project is finished, the schema is compressed to remove unnecessary data from the synchronization project. This can speed up the loading of the synchronization project. Deleted schema data can be added to the synchronization configuration again at a later point.
If the target system schema or the One Identity Manager schema has changed, these changes must also be added to the synchronization configuration. Then the changes can be added to the schema property mapping.
To include schema data that have been deleted through compression and schema modifications in the synchronization project, update each schema in the synchronization project. This may be necessary if:
To update a system connection schema
-
In the Synchronization Editor, open the synchronization project.
-
Select the Configuration > Target system category.
- OR -
Select the Configuration > One Identity Manager connection category.
-
Select the General view and click Update schema.
- Confirm the security prompt with Yes.
This reloads the schema data.
To edit a mapping
-
In the Synchronization Editor, open the synchronization project.
-
Select the Mappings category.
-
Select a mapping in the navigation view.
Opens the Mapping Editor. For more information about mappings, see the One Identity Manager Target System Synchronization Reference Guide.
NOTE: The synchronization is deactivated if the schema of an activated synchronization project is updated. Reactivate the synchronization project to synchronize.