The SDK includes a sample script used to reload the Web Interface. This script builds a URL based on the server and web interface and uses an HTTP GET to force the Web Interface to reload. The URL the script builds is: http://
WORKAROUND
Please perform following steps:
1) Open web.config
a. You will find this in C:\Program Files\Dell\Active Roles\7.0\Web\Public or where Web Interface is installed
2) Go to <system.webServer> section
3) With in that go to <handlers> section
4) Add the following statement in <handlers> section
<add name="ReloadMetadata.aspx_*" verb="*" path="ReloadMetadata.aspx" type="ActiveRoles.Web.Application.Customization.MetadataReloader" preCondition="integratedMode"/>
STATUS:
This will be fixed on a future release of the product.