From the TPAM Administration Guide (versions 2.5.919 and below), this field must meet the following:
The time windows entered indicate the time(s) the password is
scheduled to be changed. Time windows are entered as
Starttime-EndTime. Times must be entered using a 24 hour
format. Multiple time windows may be entered separated by a
semi-colon. Up to 4 windows may be entered. Each window
must be a minimum of 60 minutes long, and there must be at
least 30 minutes in between each window. Windows that cross
midnight will be listed as two separate windows once the
profile is saved. Based on the time windows entered, the total
number of minutes per day that the change can be scheduled is
displayed on the right. A schedule must allow at least 4 hours
per day when it can be run.
Make corrections to this field so that it meets the above requirements.
TPAM 2.5.920 has adjusted the requirements on the Password Check and Change profiles; from the 2.5.920 Release Notes:
"On password check and change profiles changed the minimum length of window to 15 minutes, and changed the minimum period between windows to 5 minutes." BFER 9477
From the 2.5.920 Administrator Guide:
The time windows entered indicate the time(s) the password is scheduled to be checked. Time windows are entered as StartTime-EndTime. Times must be entered using a 24 hour format. Multiple time windows may be entered separated by a semi-colon. Up to 4 windows may be entered. Each window must be a minimum of 15 minutes long, and there must be at least 5 minutes in between each window. Windows that cross midnight will be listed as two separate windows once the profile is saved. Based on the time windows entered, the total number of minutes per day that the check can be scheduled is displayed on the right. A schedule must allow at least 4 hours per day when it can be run.