Setting up the hardware appliance
|
CAUTION: To maximize security, restrict the access to MGMT interface to as few users as possible. The Management web kiosk gives access to functions without authentication, such as pulling a support bundle or rebooting the appliance. |
Follow these steps to set up and configure the One Identity Safeguard for Privileged Passwords Appliance.
Step 1: Before you start
Ensure that you install the Microsoft .NET Framework 4.6 (or later) on your management host.
Step 2: Prepare for installation
Gather the following items before you start the appliance installation process:
- Laptop
- IP address
- IP subnet mask
- IP gateway
- DNS server address
- NTP server address
-
One Identity Safeguard for Privileged Passwords license
If you purchased One Identity Safeguard for Privileged Passwords, the appropriate license files should have been sent to you via email. If you have not received an email or need it to be resent, visit https://support.oneidentity.com/contact-us/licensing. If you need to request a trial key, please send a request to sales@oneidentity.com or call +1-800-306-9329.
Step 3: Rack the appliance
Prior to installing the racks for housing the appliance, refer to the Warnings and precautions appendix in the One Identity Safeguard Appliance Setup Guide provided in the box with the hardware equipment.
Step 4: Power on the appliance
Prior to powering up the appliance, see the Standardized warning statements for AC systems appendix in the One Identity Safeguard Appliance Setup Guide.
The One Identity Safeguard for Privileged Passwords Appliance includes dual power supplies for redundant AC power and added reliability.
-
Plug the power cords to the power supply sockets on the appliance back and then connect the cords to AC outlets.
TIP: As a best practice, connect the two power cords to outlets on different circuits. One Identity recommends using an UPS on all appliances.
-
Press the Green check mark button on the front panel of the appliance for NO MORE THAN one second to power on the appliance.
|
Caution: Once the Safeguard for Privileged Passwords Appliance is booted, DO NOT press and hold the Green check mark button. Holding this button for four or more seconds will cold reset the power of the appliance and may result in damage. |
You can use the Red X button to shut down the appliance. Once the Safeguard for Privileged Passwords Appliance is booted, press and hold the Red X button for four seconds until it displays POWER OFF.
NOTE: If the Safeguard for Privileged Passwords Appliance is not yet booted, it may be necessary to press the Red X button for up to 13 seconds.
|
Caution: Once the Safeguard for Privileged Passwords Appliance is booted, DO NOT press and hold the Red X button for more than 13 seconds. This will hard power off the appliance and may result in damage. |
Step 5: Connect the management host to the appliance
The port used for a secure first-time configuration of the appliance is MGMT. This IP address is a fixed address that cannot be changed. It will always be available in case the primary interface becomes unavailable. The MGMT IP address is: 192.168.1.105.
The primary interface that connects your appliance to the network is X0. You must change the primary interface IP to match your network configuration. The default X0 IP is: 192.168.0.105.
The appliance can take up to five minutes to boot up. In addition, ping replies have been disabled on the appliance, so you will not be able to ping this secure appliance.
- Connect an Ethernet cable from the laptop to the MGMT port on the back of the appliance.
-
Set the IP address of the laptop to 192.168.1.100, the subnet mask to 255.255.255.0, and no default gateway.
Step 6: Log in to Safeguard for Privileged Passwords
-
Open a browser on the laptop and connect to the IP address of the MGMT port https://192.168.1.105.
If you have problems accessing the configuration interface, check your browser Security Settings or try using an alternate browser.
-
Accept the certificate and continue. This is only safe when using an Ethernet cable connected directly to the appliance.
- Log in to the Safeguard for Privileged Passwords web client using the Bootstrap Administrator account:
- User name: admin
-
Password: Admin123
The Bootstrap Administrator is a built-in account that allows you to get the appliance set up for first-time use. To keep your Safeguard for Privileged Passwords Appliance secure, change the default password for the Bootstrap Administrator’s account. For more information, see Completing the appliance setup.
- Configure the primary network interface (X0): On the Appliance Configuration page, configure the following. Click the Edit icon to modify these settings.
- On the Appliance Configuration page, configure the following. Click the Edit icon to modify these settings.
-
Time: Enable NTP and set the primary NTP server; if desired, set the secondary NTP server, as well. Click Save. By default, the NTP server is set to pool.ntp.org.
- Network (X0):
- Log in and download the desktop client to complete the next steps. For more information, see Completing the appliance setup.
Step 7: Connect the appliance to the network
- Connect an Ethernet cable from your primary interface (X0) on the appliance to your network.
Warnings and precautions
The following precautions must be taken for proper installation.
Rack precautions
- Ensure that the leveling jacks on the bottom of the rack are fully extended to the floor with the full weight of the rack resting on them.
- In a single-rack assembly, stabilizers should be attached to the rack. In a multi-rack assembly, the racks should be coupled together.
- Always ensure the rack is stable before extending a component from the rack.
- Extend only one component at a time; extending two or more components simultaneously may cause the rack to become unstable.
Component precautions
- Review the electrical and general safety precautions. For more information, see Standardized warning statements for AC systems.
- Determine the placement of each component in the rack BEFORE you install the rails.
- Install the heaviest components on the bottom of the rack first, and then work up.
- Use a regulating uninterruptible power supply (UPS) to protect the component from power surges, voltage spikes, and to keep your system operating in case of a power failure.
- Allow the hot plug SATA drives and power supply modules to cool before touching them.
- Always keep the rack's front door and all panels and components on the appliance closed when not servicing to maintain proper cooling.
Appliance and mounting considerations
The following conditions are required for proper installation.
Ambient operating temperature
If installed in a closed or multi-rack assembly, the ambient operating temperature of the rack environment may be greater than the ambient temperature of the room. Therefore, consideration should be given to installing the equipment in an environment compatible with the manufacturer's maximum rated ambient temperature (Tmra).
Reduced airflow
Mount the equipment into the rack so that the amount of airflow required for safe operation is not compromised.
Mechanical loading
Mount the appliances evenly in the rack in order to prevent a hazardous condition due to uneven mechanical loading.
Circuit overloading
Consideration must be given to the connection of the equipment to the power supply circuit. Appropriate consideration of equipment nameplate ratings must be used when addressing this concern. Do not overload the circuit.
Reliable ground
Reliable grounding of rack-mounted equipment must be maintained at all times. To ensure this, the rack itself should be grounded. Particular attention must be given to power supply connections other than the direct connections to the branch circuit, such as power strips.
Standardized warning statements for AC systems
The following statements are industry-standard warnings, provided to warn the user of situations that have the potential for bodily injury. Should you have questions or experience difficulty, contact One Identity technical support for assistance. Only certified technicians should attempt to install or configure components.
Read this appendix in its entirety BEFORE installing or configuring components in the One Identity Safeguard for Privileged Passwords Appliance.
Warning definition
|
Warning: This warning symbol means danger. You are in a situation that could cause bodily injury. Before you work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents. |
Installation instructions
|
Warning: Read the installation instructions before connecting the system to the power source. |
Circuit Breaker
|
Warning: This product relies on the building's installation for short-circuit (overcurrent) protection. Ensure that the protective device is rated not greater than 250 V, 20 A. |
Power Disconnection Warning
|
Warning: The system must be disconnected from all sources of power and the power cord removed from the power supply module(s) before accessing the chassis interior to install or remove system components. |
Equipment installation
|
Warning: Only trained and qualified personnel should be allowed to install, replace, or service this equipment. |
Restricted area
|
Warning: This unit is intended for installation in restricted access areas. A restricted access area can be accessed only through the use of a special tool, lock and key, or other means of security. (This warning does not apply to workstations.) |
Battery handling
|
Warning: There is a danger of explosion if the battery is replaced incorrectly. Replace the battery only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer's instructions. |
Redundant power supplies
|
Warning: This unit may have more than one power supply connection. All connections must be removed to de-energize the unit. |
Backplane voltage
|
Warning: Hazardous voltage or energy is present on the backplane when the system is operating. Use caution when servicing. |
Comply with local and national electrical codes
|
Warning: Installation of equipment must comply with local and national electrical codes. |
Product disposal
|
Warning: Ultimate disposal of this product should be handled according to all national laws and regulations. |
Hot swap fan warning
|
Warning: The fans may still be turning when you remove the fan assembly from the chassis. Keep fingers, screwdrivers, and other objects away from the openings in the fan assembly's housing. |
Power cable and AC adapter
|
Warning: When installing the product, use the provided or designated connection cables, power cables, and AC adapters. Using any other cables and adapters can cause a malfunction or a fire. Electrical Appliance and Material Safety Law prohibits the use of UL or CSA-certified cables (which have UL/CSA shown on the code) for any other electrical devices than products designed by One Identity LLC only. |
Virtual machine
Safeguard for Privileged Passwords can be run from:
- The One Identity Safeguard for Privileged Passwords 3000 Appliance or 2000 Appliance (hardware)
- A virtual machine
- The cloud
This section covers the background and steps you need to set up the virtual machine for the first time.