Chatee ahora con Soporte
Chat con el soporte

Identity Manager 9.1 - Target System Synchronization Reference Guide

Target system synchronization with the Synchronization Editor Working with the Synchronization Editor Basics of target system synchronization Setting up synchronization
Starting the Synchronization Editor Creating a synchronization project Configuring synchronization
Setting up mappings Setting up synchronization workflows Connecting systems Editing the scope Using variables and variable sets Setting up start up configurations Setting up base objects
Overview of schema classes Customizing the synchronization configuration Checking the consistency of the synchronization configuration Activating the synchronization project Defining start up sequences
Running synchronization Synchronization analysis Setting up synchronization with default connectors Updating existing synchronization projects Script library for synchronization projects Additional information for experts Troubleshooting errors when connecting target systems Configuration parameters for target system synchronization Configuration file examples

Run Synchronization Editor without target system connection

Sometimes is not necessary to access the connected systemClosed with the Synchronization EditorClosed. In this case the Synchronization Editor can be run with a disconnected target system connection. For example, connection configurations can be viewed and edited without the One Identity Manager attempting to connect to the system in question. However, Synchronization Editor functions, which absolutely require a system connection, cannot be run or cannot be run correctly with it.

To start the Synchronization Editor without target system connection

  1. Start a command line program and go to the One Identity Manager installation directory.
  2. Run the Synchronization Editor with the -o option.

    SynchronizationEditor.exe -o

The target system connection is disconnected by default. The Disconnected button on the toolbar allows you to cancel the disconnect and reconnect.

Related topics

Working with an encrypted database

When you set up a synchronization projectClosed in an encrypted One Identity Manager database, sensitive data is encrypted. This affects passwords for connection data as well as variables that are labeled as secret. The Synchronization EditorClosed requires all connection data in decrypted form in order to access connected systemsClosed. You can nevertheless open the synchronization project and edit it partially.

If the Synchronization Editor now accesses the connection system, it cannot establish a system connection because certain connection parameters are encrypted. The values can be decrypted through an appropriately configured remote connection. Set up a remote connection server to do this. For more information, see Establish remote connection. Note here the relevant restrictions for setting up a remote connection server.

To enable the system connection despite encrypted connection data

  1. Edit the system connection.

    For more information, see How to edit system connection properties.

    An extra dialog box is displayed.

  2. Set the first option and click OK.

    1. Enter the remote connection properties.

      For more information, see Remote connection properties.

    2. Click Connect.

      This sets up the remote connection. The connection remains in place for as long as the synchronization project is open in the Synchronization Editor.

NOTE: If a remote connection is not possible, you have the option, at this point, to enter values for establishing the system connection.

  • Set the second option for this and enter the missing values. Click OK.

To decrypt encrypted values by default when you open a synchronization project

  • In the DesignerClosed, set the "DPR | UI | EncryptedValueHandling" configuration parameterClosed and select the value "ByUser" on the Options tab.

    The user can decide whether encrypted values should be ignored or not.

Table 18: Decryption dialog
Property Description
Encrypted value Value required by the connector to establish a system connection.
Ignore this value Specifies whether to ignore the value. The synchronization project can be selectively edited. However, all actions which required accessing the connected system, cannot be run.
Show values Specifies whether the values entered are shown. If this option is not set, input is masked.
Remember the values and save locally Specifies whether the data entered is saved locally. The next time the synchronization project is opened, the stored values are applied and can be confirmed or altered.

IMPORTANT: If an encrypted value has been changed in the One Identity Manager database, the changed value must also be changed on the workstation as soon as the synchronization project is next opened.

Otherwise, the value is overwritten by the locally stored data when the synchronization project is saved. Modifications (of passwords, for example) go missing this way!

To avoid overwriting

  • Update the pre-set values and enable the Remember the values and save locally option.

To delete locally saved data

  1. Select the Database > Settings... menu item.
  2. Select the Security tab.
  3. Select a value and click Delete.

Ignore all

Ignores encrypted values and open the synchronization project.

Changing a synchronization user's password

One Identity Manager provides a system user with all the permissions necessary to set up target system synchronizationClosed through an application server and to run it. When you set up the One Identity Manager database, you entered a password for the Synchronization system user. You can change this password in the Synchronization EditorClosed. The password must then be changed in all synchronization projectsClosed that connect to the database through an application server. One Identity Manager can try to update these passwords automatically. If this is not possible, modify the synchronization projects manually.

IMPORTANT: The password may not be changed while synchronization is starting up or running. Only change the password outside working hours!

Only passwords that are managed in One Identity Manager can be changed. There is no menu item shown for externally managed passwords. For more information about managing system user passwords, see the One Identity Manager Authorization and Authentication Guide.

To change the system user's Password

  1. Select the Database > Change synchronization user password menu item.
  2. Enter the required data:
  3. Click OK.
Table 19: Password data
Property Description
Old password Password valid until now.
New password and password confirmation New password for the system user to log on to the database.
Show passwords Passwords are not masked.
Try to update existing synchronization projects One Identity Manager checks all the synchronization projects and tries to update the password. The password is only changed in synchronization projects that are connected with the database through an application server.

To manually update the database connection password

  1. Open the synchronization project which needs to have its password updated.
  2. Select the Configuration > One Identity Manager connection category.
  3. Confirm the prompt with OK.

    Do not establish a remote connection.

  4. Click Edit connection.
  5. Select the Connection parameter page in the system connection wizard.
  6. Enter the new password in Synchronization user's password.
  7. Click Test.
  8. If the connection is successfully established, click Next.
  9. Close the system connection wizard.
  10. Save the changes.

Basics of target system synchronization

To configure target system synchronizationClosed you must have knowledge of the One Identity Manager's basic procedure for synchronizing and provisioning data. These basics are explained in the following sections.

Table 20: Basic synchronization terminology

Term

Described in

Dependency resolution

How does dependency resolution work?

Outstanding objects

Deleting objects in One Identity Manager

Synchronization of single objectsClosed

Synchronization and provisioning

FilterClosed

What are filters?

Mapping directionClosed

Direction of synchronization and mapping

Mapping against the direction of synchronization

Primary and secondary systems

Synchronizing user data with different systems

ProvisioningClosed

Synchronization and provisioning

Revision filterClosed

How does revision filtering work?

SchemaClosed

How are schemas mapped

ScopeClosed

What is a scope?

Direction of synchronization

Direction of synchronization and mapping

Rogue modificationClosed

Detecting rogue modifications

Documentos relacionados

The document was helpful.

Seleccionar calificación

I easily found the information I needed.

Seleccionar calificación