Tchater maintenant avec le support
Tchattez avec un ingénieur du support

Identity Manager 9.0 LTS - Administration Guide for Connecting to Oracle E-Business Suite

Mapping an Oracle E-Business Suite in One Identity Manager Synchronizing Oracle E-Business Suite
Setting up initial synchronization of Oracle E-Business Suite Customizing the synchronization configuration Running synchronization Tasks following synchronization Troubleshooting Ignoring data error in synchronization Pausing handling of target system specific processes (Offline mode)
Managing E-Business Suite user accounts and employees Login information Managing entitlement assignments Mapping of E-Business Suite objects in One Identity Manager Handling of E-Business Suite objects in the Web Portal Basic configuration data Configuration parameters for managing Oracle E-Business Suite Permissions required for synchronizing with Oracle E-Business Suite Default project templates for synchronizing an Oracle E-Business Suite Editing system objects Example of a schema extension file

Post-processing outstanding objects

Objects, which do not exist in the target system, can be marked as outstanding in One Identity Manager by synchronizing. This prevents objects being deleted because of an incorrect data situation or an incorrect synchronization configuration.

Outstanding objects:

  • Cannot be edited in One Identity Manager.

  • Are ignored by subsequent synchronizations.

  • Are ignored by inheritance calculations.

This means, all memberships and assignments remain intact until the outstanding objects have been processed.

Start target system synchronization to do this.

To post-process outstanding objects

  1. In the Manager, select the Oracle E-Business Suite > Target system synchronization: Oracle E-Business Suite category.

    The navigation view lists all the synchronization tables assigned to the Oracle E-Business Suite target system type.

  2. On the Target system synchronization form, in the Table / object column, open the node of the table for which you want to post-process outstanding objects.

    All objects that are marked as outstanding are shown. The Last log entry and Last method run columns display the time at which the last entry was made in the synchronization log and which processing method was run. The No log available entry can mean the following:

    • The synchronization log has already been deleted.

      - OR -

    • An assignment from a member list has been deleted from the target system.

      The base object of the assignment was updated during the synchronization. A corresponding entry appears in the synchronization log. The entry in the assignment table is marked as outstanding, but there is no entry in the synchronization log.

    • An object that contains a member list has been deleted from the target system.

      During synchronization, the object and all corresponding entries in the assignment tables are marked as outstanding. However, an entry in the synchronization log appears only for the deleted object.

    TIP:

    To display object properties of an outstanding object

    1. Select the object on the target system synchronization form.

    2. Open the context menu and click Show object.

  1. Select the objects you want to rework. Multi-select is possible.

  2. Click on one of the following icons in the form toolbar to run the respective method.

    Table 14: Methods for handling outstanding objects

    Icon

    Method

    Description

    Delete

    The object is immediately deleted from the One Identity Manager database. Deferred deletion is not taken into account.

    Indirect memberships cannot be deleted.

    Publish

    The object is added to the target system. The Outstanding label is removed from the object.

    This runs a target system specific process that triggers the provisioning process for the object.

    Prerequisites:

    • The table containing the object can be published.

    • The target system connector has write access to the target system.

    Reset

    The Outstanding label is removed for the object.

  3. Confirm the security prompt with Yes.

NOTE: By default, the selected objects are processed in parallel, which speeds up the selected method. If an error occurs during processing, the action is stopped and all changes are discarded.

Bulk processing of objects must be disabled if errors are to be localized, which means the objects are processed sequentially. Failed objects are named in the error message. All changes that were made up until the error occurred are saved.

To disable bulk processing

  • Disable the icon in the form's toolbar.

NOTE: The target system connector must have write access to the target system in order to publish outstanding objects that are being post-processed. That means, the Connection is read-only option must not be set for the target system connection.

Adding custom tables to the target system synchronization

You must customize your target system synchronization to synchronize custom tables.

To add tables to target system synchronization

  1. In the Manager, select the Oracle E-Business Suite > Basic configuration data > Target system types category.

  2. In the result list, select the Oracle E-Business Suite target system type.

  3. Select the Assign synchronization tables task.

  4. In the Add assignments pane, assign custom tables to the outstanding objects you want to handle.

  5. Save the changes.
  6. Select the Configure tables for publishing task.

  7. Select the custom tables that contain the outstanding objects that can be published in the target system and set the Publishable option.

  8. Save the changes.
Related topics

Troubleshooting

Synchronization Editor helps you to analyze and eliminate synchronization errors.

  • Simulating synchronization

    The simulation allows you to estimate the result of synchronization. This means you can, for example, recognize potential errors in the synchronization configuration.

  • Analyzing synchronization

    You can generate the synchronization analysis report for analyzing problems which occur during synchronization, for example, insufficient performance.

  • Logging messages

    One Identity Manager offers different options for logging errors. These include the synchronization log, the log file for One Identity Manager Service, the logging of messages with NLOG, and similar.

  • Reset start information

    If synchronization stopped unexpectedly, for example, because a server was not available, the start information must be reset manually. Only then can the synchronization be restarted.

  • Resetting revisions

    It may also be necessary to process those objects during synchronization, whose change information has not been updated since the last synchronization. This might be required if changes to data were made without the change information for the object being updated, for example. This means, the change information for objects becomes older than that saved in the synchronization project. In such cases, the revision for a start up configuration can be reset.

For more information about these topics, see the One Identity Manager Target System Synchronization Reference Guide.

Related topics

Ignoring data error in synchronization

By default, objects with incorrect data are not synchronized. These objects can be synchronized once the data has been corrected. In certain situations, however, it might be necessary to synchronize objects like these and ignore the data properties that have errors. This synchronization behavior can be configured in One Identity Manager.

To ignoring data errors during synchronization in One Identity Manager

  1. In the Synchronization Editor, open the synchronization project.

  2. Select the Configuration > One Identity Manager connection category.

  3. In the General view, click Edit connection.

    This starts the system connection wizard.

  4. On the Additional options page, enable Try to ignore data errors.

    This option is only effective if Continue on error is set in the synchronization workflow.

    Default columns, such as primary keys, UID columns, or mandatory input columns cannot be ignored.

  5. Save the changes.

IMPORTANT: If this option is set, One Identity Manager tries to ignore commit errors that could be related to data errors in a single column. This causes the data changed in the affected column to be discarded and the object is subsequently saved again. This effects performance and leads to loss of data.

Only set this option in the exceptional circumstance of not being able to correct the data before synchronization.

Documents connexes

The document was helpful.

Sélectionner une évaluation

I easily found the information I needed.

Sélectionner une évaluation