Introducing Safeguard for Sudo Planning Deployment Installation and Configuration Upgrade Safeguard for Sudo System Administration Managing Security Policy Administering Log and Keystroke Files Troubleshooting Safeguard Variables Safeguard programs Installation Packages Unsupported Sudo Options Safeguard for Sudo Policy Evaluation

eventlog

Description

Type string READ/WRITE

eventlog contains the full pathname of the file in which audit events are logged. The default pathname is /var/opt/quest/qpm4u/pmevents.db.

Related Topics

event

Event logging

iolog

Description

Type string READ/WRITE

iolog is the full path name of the keystroke log file in which input, output, and error output is logged.

logstderr

Description

Type integer READ/WRITE

Set logstderr to true to enable keystroke logging of stderr output produced during the session. The default value is true.

Related Topics

logstdin

logstdout

logstdin

Description

Type integer READ/WRITE

Set logstdin to true to enable keystroke logging of stdin input produced during the session. The default value is true.

Related Topics

logstderr

logstdout