Reset the license counter
Descrizione
The allowed amount of hosts by the license is exceeded because of various reasons, like:
an issue in the log sending infrastructure filled up the list with unexpected host names,
already removed hosts kept in the list reserving the place in front of current legit log hosts,
etc.
Causa
The licensing subsystem keeps track all the hosts that are sending messages directly or being present as log sender hosts in the log messages. The list is ever increasing and has the new hosts appended regardless of the time of the last successful log retrieval.
Risoluzione
The license counter can be reseted by restarting the underlying syslog-ng process on the appliance.
This can be achieved two ways by either
navigating to Basic Settings > System > Service control and pressing the "Restart syslog-ng" button.
rebooting the appliance (not recommended in this case)
Feedback inviato
Questo articolo ti è servito per risolvere il problema?
Data di creazione: 3/7/2019 Ultimo aggiornamento: 5/7/2023
Thank you for your feedback for Topic Request
Your Request will be reviewed by our technical reviewer team and, if approved, will be added as a Topic in our Knowledgebase.
Questo è il portale del supporto
Puoi trovare aiuto e supporto online per *prodotto* sul sito di supporto di un affiliato. Fai clic su Continua per essere reindirizzato ai contenuti e all'assistenza corretti per *prodotto*.
Internet Explorer 8, 9 e 10 non sono più supportati
Il portale One Identity non supporta più Internet Explorer 8, 9, e 10. Si consiglia di aggiornare il browser all'ultima versione di Internet Explorer o Chrome.