When the slots are shut down due to the Configuration Parameter QBM\DBQueue\KeepAlive value being reached, DialogJournal messages of this type may occur more frequently:
"#LDS#Dead slot resetted, number={0}, type = {1}, Task = {2}, code = {3}.| 4|DeadTest|<none>| 2|"
code=2 means there is a task in QBMDBQueueCurrent for a slot that is no longer working, but the task is <none>.
The most likely cause:
The MAIN-Agent causes the shutdown of the slots when the KeepAlive value is reached. However, in between comes the WatchDog, which detects dead slots, and it detects the slots that are being shut down at that moment. This situation should not be detected by the DeadSlot detection at all.
This is a product defect (33460).
WORKAROUND
None
STATUS
This will be fixed in a future release of the product. If you require this immediately corrected, please contact Support for a hotfix referencing the defect ID 33460.