Submitting forms on the support site are temporary unavailable for schedule maintenance. If you need immediate assistance please contact technical support. We apologize for the inconvenience.
Error: "There is at least one object in Base objects for system connections whose property Synchronization server references this object from Job servers" (4369899)
Error: "There is at least one object in Base objects for system connections whose property Synchronization server references this object from Job servers"
설명
When attempting to delete an unwanted job server from within Designer the following error is displayed:
"There is at least one object in Base objects for system connections whose property Synchronization server references this object from Job servers"
원인
The job server is set as the synchronization server for at least one synchronization project, so it cannot be deleted.
해결 방안
Follow the steps below to update the synchronization server for each synchronization project, as required:
1. Open synchronization editor and login with an applicable account, e.g. an Identity.
2. Click on a synchronization project.
3. Click on Base objects.
4. Double left click on the available entry.
5. Click the drop down arrow next to Synchronization server.
6. Set the applicable job server.
7. Click the Ok button.
8. Repeat the steps for the any other synchronization projects.