지금 지원 담당자와 채팅
지원 담당자와 채팅

Identity Manager 9.2.1 - Administration Guide for Connecting to SharePoint

Managing SharePoint environments Setting up SharePoint farm synchronization Basic data for managing a SharePoint environment SharePoint farms SharePoint web applications SharePoint site collections and sites SharePoint user accounts SharePoint roles and groups
SharePoint groups SharePoint roles and permission levels
Permissions for SharePoint web applications Reports about SharePoint objects Configuration parameters for managing a SharePoint environment Default project template for SharePoint

Configuring synchronization of several SharePoint farms

Prerequisites

  • The target system schema of both farms are identical.
  • All virtual schema properties used in the mapping must exist in the extended schema of both farms.

To customize a synchronization project for synchronizing another farm

  1. Install and configure a synchronization server for the other farm. Declare this server as Job server in the One Identity Manager.
  2. Prepare a user account with sufficient permissions for synchronizing in the other farm.
  3. Synchronize the Active Directory or LDAP environment, the other farm is going to run on.
  4. Start the Synchronization Editor on the synchronization server of the other farm and log in on the One Identity Manager database.
  5. Open the synchronization project.
  1. Create a new base object for the other farm.

    • Use the wizard to attach a base object.

    • In the wizard, select the SharePoint connector.

    • Declare the connection parameters. The connection parameters are saved in a special variable set.

    A start up configuration is created that uses the newly created variable set.

  2. Change other elements of the synchronization configuration as required.

  3. Save the changes.
  4. Run a consistency check.

Detailed information about this topic

Changing system connection settings of SharePoint farms

When you set up synchronization for the first time, the system connection properties are set to default values that you can modify. There are two ways to do this:

  1. Specify a specialized variable set and change the values of the affected variables.

    The default values remain untouched in the default variable set. The variables can be reset to the default values at any time. (Recommended action).

  2. Edit the target system connection with the system connection wizard and change the effected values.

    The system connection wizard supplies additional explanations of the settings. The default values can only be restored under particular conditions.

Detailed information about this topic

Editing connection parameters in the variable set

The connection parameters were saved as variables in the default variable set when synchronization was set up. You can change the values in these variables to suit you requirements and assign the variable set to a start up configuration and a base object. This means that you always have the option to use default values from the default variable set.

NOTE: To guarantee data consistency in the connected target system, ensure that the start-up configuration for synchronization and the base object for provisioning use the same variable set. This especially applies if a synchronization project is used for synchronizing different SharePoint farms.

To customize connection parameters in a specialized variable set

  1. In the Synchronization Editor, open the synchronization project.

  2. Select the Configuration > Target system category.

  3. Open the Connection parameters view.

    Some connection parameters can be converted to variables here. For other parameters, variables are already created.

  4. Select a parameter and click Convert.

  5. Select the Configuration > Variables category.

    All specialized variable sets are shown in the lower part of the document view.

  6. Select a specialized variable set or click on in the variable set view's toolbar.

    • To rename the variable set, select the variable set and click the variable set view in the toolbar . Enter a name for the variable set.

  7. Select the previously added variable and enter a new value.

  8. Select the Configuration > Start up configurations category.

  9. Select a start up configuration and click Edit.

  10. Select the General tab.

  11. Select the specialized variable set in the Variable set menu.

  12. Select the Configuration > Base objects category.

  13. Select the base object and click .

    - OR -

    To add a new base object, click .

  14. Select the specialized variable set in the Variable set menu.

  15. Save the changes.

For more information about using variables and variable sets, or restoring default values and adding base objects, see the One Identity Manager Target System Synchronization Reference Guide.

Related topics

Editing target system connection properties

You can also use the system connection wizard to change the connection parameters. If variables are defined for the settings, the changes are transferred to the active variable set.

NOTE: In the following circumstances, the default values cannot be restored:

  • The connection parameters are not defined as variables.

  • The default variable set is selected as an active variable set.

In both these cases, the system connection wizard overwrites the default values. They cannot be restored at a later time.

To edit connection parameters using the system connection wizard

  1. In the Synchronization Editor, open the synchronization project.

  2. In the toolbar, select the active variable set to be used for the connection to the target system.

    NOTE: If the default variable set is selected, the default values are overwritten and cannot be restored at a later time.

  3. Select the Configuration > Target system category.

  4. Click Edit connection.

    This starts the system connection wizard.

  1. Follow the system connection wizard instructions and change the relevant properties.

  2. Save the changes.
Related topics
관련 문서

The document was helpful.

평가 결과 선택

I easily found the information I needed.

평가 결과 선택