Converse agora com nosso suporte
Chat com o suporte

Identity Manager 9.1.3 - Administration Guide for Integration with OneLogin Cloud Directory

Integration with OneLogin Cloud Directory Synchronizing a OneLogin domain
Setting up initial synchronization with a OneLogin domain Customizing the synchronization configuration Running synchronization Tasks following synchronization Troubleshooting Ignoring data error in synchronization Pausing handling of target system specific processes (Offline mode)
Managing OneLogin user accounts and employees Managing memberships in OneLogin roles Login information for OneLogin user accounts Mapping OneLogin objects in One Identity Manager
OneLogin domains OneLogin user accounts OneLogin applications OneLogin roles OneLogin authentication methods OneLogin service providers OneLogin clients OneLogin scopes OneLogin policies OneLogin groups OneLogin privileges OneLogin custom user fields Reports about OneLogin objects
Handling of OneLogin objects in the Web Portal Base data for OneLogin domains Configuration parameters for managing OneLogin domains Default template for OneLogin domains Editing OneLogin system objects OneLogin connector settings

Configuring synchronization in OneLogin domains

The synchronization project for initial synchronization provides a workflow for initial loading of target system objects (initial synchronization) and one for provisioning object modifications from the One Identity Manager database to the target system (provisioning). To use One Identity Manager as the primary system during synchronization, you also require a workflow with synchronization in the direction of the Target system.

To create a synchronization configuration for synchronizing OneLogin domains

  1. In the Synchronization Editor, open the synchronization project.

  2. Check whether the existing mappings can be used to synchronize into the target system. Create new maps if required.

  3. Create a new workflow with the workflow wizard.

    This creates a workflow with Target system as its direction of synchronization.

  4. Create a new start up configuration. Use the new workflow to do this.

  5. Save the changes.
  6. Run a consistency check.

Detailed information about this topic

Configuring synchronization of several OneLogin domains

In some circumstances, it is possible to use a synchronization project to synchronize different OneLogin domains.

Prerequisites
  • The target system schema of both domains are identical.

  • All virtual schema properties used in the mapping must exist in the extended schema of both domains.

To customize a synchronization project for synchronizing another domain

  1. Prepare a user account with sufficient permissions for synchronizing in the other domain.

  2. In the Synchronization Editor, open the synchronization project.

  1. Create a new base object for every other domain.

    • Use the wizard to attach a base object.

    • In the wizard, select the OneLogin connector.

    • Declare the connection parameters. The connection parameters are saved in a special variable set.

    A start up configuration is created that uses the newly created variable set.

  2. Change other elements of the synchronization configuration as required.

  3. Save the changes.
  4. Run a consistency check.

Related topics

Changing system connection settings of OneLogin domains

When you set up synchronization for the first time, the system connection properties are set to default values that you can modify. There are two ways to do this:

  1. Specify a specialized variable set and change the values of the affected variables.

    The default values remain untouched in the default variable set. The variables can be reset to the default values at any time. (Recommended action).

  2. Edit the target system connection with the system connection wizard and change the effected values.

    The system connection wizard supplies additional explanations of the settings. The default values can only be restored under particular conditions.

Detailed information about this topic

Editing connection parameters in the variable set

The connection parameters were saved as variables in the default variable set when synchronization was set up. You can change the values in these variables to suit you requirements and assign the variable set to a start up configuration and a base object. This means that you always have the option to use default values from the default variable set.

NOTE: To guarantee data consistency in the connected target system, ensure that the start-up configuration for synchronization and the base object for provisioning use the same variable set. This especially applies if a synchronization project is used for synchronizing different OneLogin domains.

To customize connection parameters in a specialized variable set

  1. In the Synchronization Editor, open the synchronization project.

  2. Select the Configuration > Target system category.

  3. Open the Connection parameters view.

    Some connection parameters can be converted to variables here. For other parameters, variables are already created.

  4. Select a parameter and click Convert.

  5. Select the Configuration > Variables category.

    All specialized variable sets are shown in the lower part of the document view.

  6. Select a specialized variable set or click on in the variable set view's toolbar.

    • To rename the variable set, select the variable set and click the variable set view in the toolbar . Enter a name for the variable set.

  7. Select the previously added variable and enter a new value.

  8. Select the Configuration > Start up configurations category.

  9. Select a start up configuration and click Edit.

  10. Select the General tab.

  11. Select the specialized variable set in the Variable set menu.

  12. Select the Configuration > Base objects category.

  13. Select the base object and click .

    - OR -

    To add a new base object, click .

  14. Select the specialized variable set in the Variable set menu.

  15. Save the changes.

For more information about using variables and variable sets, or restoring default values and adding base objects, see the One Identity Manager Target System Synchronization Reference Guide.

Related topics
Documentos relacionados

The document was helpful.

Selecione a classificação

I easily found the information I needed.

Selecione a classificação