Chat now with support
Chat mit Support

Identity Manager 9.2.1 - Administration Guide for Privileged Account Governance

About this guide Managing a Privileged Account Management system in One Identity Manager Synchronizing a Privileged Account Management system
Setting up the initial synchronization of a One Identity Safeguard Customizing the synchronization configuration for One Identity Safeguard Running synchronization Tasks following synchronization Troubleshooting Ignoring data error in synchronization Pausing handling of target system specific processes (Offline mode)
Managing PAM user accounts and identities Managing assignments of PAM user groups Login credentials for PAM user accounts Mapping PAM objects in One Identity Manager
PAM appliances PAM user accounts PAM user groups PAM assets PAM asset groups PAM asset accounts PAM directory accounts PAM account groups PAM directories PAM partitions PAM entitlements PAM access request policies Reports about PAM objects
PAM access requests Handling of PAM objects in the Web Portal Basic data for managing a Privileged Account Management system Configuration parameters for managing a Privileged Account Management system Default project template for One Identity Safeguard Editing One Identity Safeguard system objects One Identity Safeguard connector settings Known issues about connecting One Identity Safeguard appliances

Configuring synchronization of multiple One Identity Safeguard appliances

In some circumstances, it is possible to use a synchronization project to synchronize multiple appliances.

Prerequisites
  • The target system schemas of the appliances are identical.

  • All virtual schema properties used in the mapping must exist in the extended schemas of the appliances.

  • The connection parameters to the target system are defined as variables.

To customize a synchronization project for synchronizing another appliance

  1. Set up a user with sufficient permissions in the additional appliance.

  2. In the Synchronization Editor, open the synchronization project.

  1. Create a new base object for the appliance.

    • Use the wizard to attach a base object.

    • In the wizard, select the One Identity Safeguard connector.

    • Declare the connection parameters. The connection parameters are saved in a special variable set.

    A start up configuration is created that uses the newly created variable set.

  2. Change other elements of the synchronization configuration as required.

  3. Save the changes.
  4. Run a consistency check.

Related topics

Changing system connection settings of One Identity Safeguard appliances

When you set up synchronization for the first time, the system connection properties are set to default values that you can modify. There are two ways to do this:

  1. Specify a specialized variable set and change the values of the affected variables.

    The default values remain untouched in the default variable set. The variables can be reset to the default values at any time. (Recommended action).

  2. Edit the target system connection with the system connection wizard and change the effected values.

    The system connection wizard supplies additional explanations of the settings. The default values can only be restored under particular conditions.

Detailed information about this topic

Editing connection parameters in the variable set

The connection parameters were saved as variables in the default variable set when synchronization was set up. You can change the values in these variables to suit you requirements and assign the variable set to a start up configuration and a base object. This means that you always have the option to use default values from the default variable set.

NOTE: To guarantee data consistency in the connected target system, ensure that the start-up configuration for synchronization and the base object for provisioning use the same variable set. This especially applies if a synchronization project is used for synchronizing different One Identity Safeguard appliances.

To customize connection parameters in a specialized variable set

  1. In the Synchronization Editor, open the synchronization project.

  2. Select the Configuration > Target system category.

  3. Open the Connection parameters view.

    Some connection parameters can be converted to variables here. For other parameters, variables are already created.

  4. Select a parameter and click Convert.

  5. Select the Configuration > Variables category.

    All specialized variable sets are shown in the lower part of the document view.

  6. Select a specialized variable set or click on in the variable set view's toolbar.

    • To rename the variable set, select the variable set and click the variable set view in the toolbar . Enter a name for the variable set.

  7. Select the previously added variable and enter a new value.

  8. Select the Configuration > Start up configurations category.

  9. Select a start up configuration and click Edit.

  10. Select the General tab.

  11. Select the specialized variable set in the Variable set menu.

  12. Select the Configuration > Base objects category.

  13. Select the base object and click .

    - OR -

    To add a new base object, click .

  14. Select the specialized variable set in the Variable set menu.

  15. Save the changes.

For more information about using variables and variable sets, or restoring default values and adding base objects, see the One Identity Manager Target System Synchronization Reference Guide.

Related topics

Editing target system connection properties

You can also use the system connection wizard to change the connection parameters. If variables are defined for the settings, the changes are transferred to the active variable set.

NOTE: In the following circumstances, the default values cannot be restored:

  • The connection parameters are not defined as variables.

  • The default variable set is selected as an active variable set.

In both these cases, the system connection wizard overwrites the default values. They cannot be restored at a later time.

To edit connection parameters using the system connection wizard

  1. In the Synchronization Editor, open the synchronization project.

  2. In the toolbar, select the active variable set to be used for the connection to the target system.

    NOTE: If the default variable set is selected, the default values are overwritten and cannot be restored at a later time.

  3. Select the Configuration > Target system category.

  4. Click Edit connection.

    This starts the system connection wizard.

  1. Follow the system connection wizard instructions and change the relevant properties.

  2. Save the changes.
Related topics
Verwandte Dokumente

The document was helpful.

Bewertung auswählen

I easily found the information I needed.

Bewertung auswählen