Privilege Manager for Unix 7.3 - Administration Guide

Introducing Privilege Manager for Unix Planning Deployment Installation and Configuration Upgrade Privilege Manager for Unix System Administration Managing Security Policy The Privilege Manager for Unix Security Policy Advanced Privilege Manager for Unix Configuration Administering Log and Keystroke Files InTrust Plug-in for Privilege Manager for Unix Troubleshooting Privilege Manager for Unix Policy File Components Privilege Manager for Unix Variables
Variable names Variable scope Global input variables Global output variables Global event log variables PM settings variables
Privilege Manager for Unix Flow Control Statements Privilege Manager for Unix Built-in Functions and Procedures
Environment functions Hash table functions Input and output functions LDAP functions LDAP API example List functions Miscellaneous functions Password functions Remote access functions String functions User information functions Authentication Services functions
Privilege Manager for Unix programs Installation Packages

iolog_opmax

Description

Type integer READ/WRITE

iolog_opmax limits the size in bytes of each stdout keystroke log entry produced during the session.

Example
if (command in {"csh","ksh"}) 
{ 
   iolog_encrypt = true; 
   log_passwords = false; 
   iolog_errmax = 10000; 
   iolog_opmax = 10000; 
   iolog = mktemp("/var/adm/pm." + user + "." + command + ".XXXXXX"); 
   accept; 
}
Related Topics

iolog

iologhost

iolog_errmax

iolog_encrypt

log_passwords

Keystroke (I/O) logging policy variables

iologhost

Description

Type string READ/WRITE

iologhost is a string that defines the host that acts as a centralized I/O log server.

Example
iologhost="sol34.test.com";
Related Topics

iolog

iolog_opmax

iolog_errmax

iolog_encrypt

log_passwords

tmplogdir

log_passwords

Description

Type integer READ/WRITE

Set log_passwords to false to disable the keystroke logging of any password entry commands detected during the session. The default value is true.

Example
if (command in {"csh","ksh"}) 
{ 
   iolog_encrypt = true; 
   log_passwords = false; 
   iolog_errmax = 10000; 
   iolog_opmax = 10000; 
   loggroup = "admin"; 
   logstderr = true; 
   logstdout = false; 
   logstdin = true; 
   iolog = mktemp("/var/adm/pm." + user + "." + command + ".XXXXXX"); 
accept; 
}
Related Topics

Keystroke (I/O) logging policy variables

logomit

Description

Type list READ/WRITE

logomit specifies a list of variable names to omit when logging to the keystroke and event log which can be useful if space is at a premium. For example, the administrator could choose to log only the runenv variable, and omit the submit env variable. The default is an empty list.

Example
logomit={ "nice" };
Related Topics

iolog

eventlog

Event logging