When a DPRStartSequence is started, a new entry is created in DPRStartSequence with ExecutionState="Running". As soon as all contained syncs are processed, the ExecutionState changes to "Processed". This also happens if a sync involved fails. However, if a sync is not terminated regularly, e.g. due to a job server crash, the ExecutionState remains at "Running".
If IsAllowMultipleInstances is not set, all subsequently started sequences will fail with:
"[1779024] Cannot create an instance of the start up sequence (AD+Exchange) because there is already an active instance. Multiple instances are not allowed for this start up sequence."
There is no regular way to reset (or delete) the canceled sequence. A correction must currently be done via SQL (or Object Browser).
The StartSequence editor in the Synchronization Editor should provide this possibility.
Additionally, it would be useful to display the runtime of the started instances as well.
An enhancement request (#33050) has been created.
WORKAROUND
Reset via SQL or Object Browser.
STATUS
The product team will evaluate the request and this feature may become available in a future release of the product.