Chatta subito con l'assistenza
Chat con il supporto

Identity Manager 8.2.1 - Operational Guide

About this guide Simulating data changes in the Manager Scheduling operations activation times Re-applying templates Exporting data with the Manager Analyzing data and data changes Analyzing process monitoring in the Manager Schedules in One Identity Manager Mail templates in One Identity Manager Password policies in One Identity Manager Working with change labels Checking data consistency Compiling a One Identity Manager database Transporting custom changes Importing data with the Data Import Importing and exporting individual files for the software update Creating a One Identity Manager database for test or development from a database backup Initializing DBQueue Processor the after extending the server hardware Command line programs

Notes on the consistency check

  • It is recommended to run consistency checks with an administrative user.

    Not all consistency checks are available for end users and configuration users.

  • To use the Consistency Editor, users need the Option to call a consistency check for a database (Common_ConsistencyCheck) program function.

  • To use the repair function in the Consistency Editor, users need the Option to start automatic consistency check repair function (Common_ConsistencyCheck_Repair) program function.

  • Consistency checks of type Object test are always run in the context of the user currently logged in. If users do not have any permissions for a certain object, errors may not be identified or repairing errors may fail.

Running consistency checks

To run a consistency check

  1. in the Designer or the Manager, start the Consistency Editor with the Database > Check data consistency menu item.

    During start up, One Identity Manager schema table definitions are loaded and database objects are made available for testing.

  2. Specify the test settings.

    1. In the Consistency Editor toolbar, click .

    2. Enable the test that is to be run and adjust the test settings further if necessary.

    3. Click OK.

    NOTE: In the Designer, the test settings dialog opens immediately after the Consistency Editor is started.

  3. Start the consistency check. The following test procedures are available in the Consistency Editor for this:

    • Checking all test objects

      Use the button to start the check.

      NOTE: To exclude individual test objects from the check, use the Disable item in the context menu to disable these test objects in the list view before the check starts.

    • Checking single test objects

      In the list view, select the relevant test objects and start this check by selecting Test.

      TIP: Use Shift + select or Ctrl + select to select more than one test object to be checked.

    NOTE: To stop a check that is in progress, click in the Consistency Editor toolbar.

  4. Verify error output.

  5. Repair errors if necessary.

Related topics

Test settings for consistency checks

Define the valid test settings before you run a consistency check. Tests are performed at database, table, and object level. There are already predefined tests available. You can run your own custom tests.

To configure the settings for testing

  1. in the Designer or the Manager, start the Consistency Editor with the Database > Check data consistency menu item.

  2. In the Consistency Editor toolbar, click .

  3. Enable the test that is to be run and adjust the test settings further if necessary.

  4. Click OK.

The tests are grouped according to different criteria.

Table 30: Meanings of the icons used for test settings
Icon Meaning

Tests are grouped by themes.

Tests are grouped by types (database, tables , objects).

Tests are displayed as a list.

Tests are grouped by module association.

Tests with Error severity are displayed.

Tests with Warning severity are displayed.

Tests with Information severity are displayed.

Use user-defined tests to run your own tests. You can use the scripts from the script library for these tests. All scripts in the script library are provided for custom tests. The method call of these scripts corresponds to the following syntax.

Database test

Public Sub Methodname (ByRef con As IConnection)

Public Sub Methodname (ByVal con As IConnection)

Table test

Public Sub Methodname (ByRef dbTable As ITableDef)

Public Sub Methodname (ByVal dbTable As ITableDef)

Object test

Public Sub Methodname (ByRef dbObject As ISingleDBObject)

Public Sub Methodname (ByVal dbObject As ISingleDBObject)

For detailed information about scripts and the script library, see the One Identity Manager Configuration Guide.

Displaying test objects and test status

When Consistency Editor is starting up, One Identity Manager schema table definitions are loaded and database objects are made available for testing. The database tables, the number of objects per table and the test status are displayed in the Consistency Editor’s list view.

TIP: To sort by a specific column, click on that column in the table header.

Figure 10: Consistency Editor with Initialized Data

Table 31: List view information
Column Meaning

Object

Test object name.

Count

Total number of objects in the database table.

Verified

Test progress in percent.

Errors

The number of error that occurred during a consistency check.

Status

Current test status. The status is updated during the consistency check.

Table 32: Meaning of list view icons
Icon Meaning

Test object is currently being test.

Consistency check was successful for this Test object.

Consistency check for this test object is complete but errors occurred.

Table 33: List view context menu items
Context menu item Meaning

Enable

Enables selected test object(s) for the period of the consistency check.

Disable

Disables selected test object(s) for the period of the consistency check.

Test

Starts running the consistency check for the selected test object(s).

Skip

Skip the test object during the consistency check.

Related Documents

The document was helpful.

Seleziona valutazione

I easily found the information I needed.

Seleziona valutazione