サポートと今すぐチャット
サポートとのチャット

Identity Manager 8.1.4 - Target System Synchronization Reference Guide

Target system synchronization with the Synchronization Editor Working with the Synchronization Editor Basics of target system synchronization Setting up synchronization
Starting the Synchronization Editor Creating a synchronization project Configuring synchronization
Setting up mappings Setting up synchronization workflows Connecting systems Editing the scope Using variables and variable sets Setting up start up configurations Setting up base objects
Overview of schema classes Customizing the synchronization configuration Checking the consistency of the synchronization configuration Activating the synchronization project Defining start up sequences
Running synchronization Synchronization analysis Setting up synchronization with default connectors Updating existing synchronization projects Script library for synchronization projects Additional information for experts Resolving errors when connecting target systems Configuration parameters for target system synchronization Configuration file examples Glossary

Configuring the synchronization log

All the information, tips, warnings, and errors that occur during synchronizationClosed are recorded in the synchronization log. You can configure the type of information to record separately for each system connection.

To configure the content of the synchronization log

  1. Edit the system connection properties.

  2. To configure the synchronization log for target system connection, select the Configuration | Target systemClosed category in Synchronization EditorClosed.

    - OR -

    To configure the synchronization log for the database connection, select the Configuration | Synchronization Editor connection category in One Identity Manager.

  3. Select the General view and click Configure.

  4. Select the Synchronization log view and set Create synchronization log.

  5. Enable the data to be logged.

    NOTE: Some content generates a particularly large volume of log data!

    The synchronization log should only contain data required for error analysis and other analyzes.

  6. Click OK.

Synchronization logs are stored for a fixed length of time.

To modify the retention period for synchronization logs

  • In the Designer, enable the DPR | Journal | LifeTime configuration parameter and enter the maximum retention period.

Detailed information about this topic

Editing the scope

In the general scope, you can specify system objects to be handled by synchronizationClosed. This allows you to limit the number of objects to synchronize. If no general scope is defined, all objects in the connected system are synchronized.

In the reference scopeClosed, you define which system objects are loaded for the reference resolution. If no reference scope is defined, the general scope is also used for the reference resolution.

TIP: If a general scope is defined, but you want all system objects of a target system type to be available, create an empty reference scope. To do this, simply enter the display name of the reference scope. This means that no scope is calculated in the reference resolution.

If the synchronization projectClosed was creating using a default project templateClosed, a scope is defined. You may edit this scope. A scope is not define if the synchronization project was created without a project template.

NOTE: To avoid data inconsistencies, define the same scope in both of the connected systems.
Detailed information about this topic

How to edit a scope

To edit the scope

  1. Edit the system connection properties.

    For more information, see How to edit system connection properties.

  2. Select the ScopeClosed view.
  3. Click Edit scope.

To edit the reference scopeClosed

  1. Edit the system connection properties.

    For more information, see How to edit system connection properties.

  2. Select the Scope view.
  3. Click Edit reference scope.

How to delete a scope

To delete the scope or scope reference.

  1. Edit the system connection properties.

    For more information, see How to edit system connection properties.

  2. Select the ScopeClosed view.
  3. Click Delete.
関連ドキュメント

The document was helpful.

評価を選択

I easily found the information I needed.

評価を選択