Starting synchronization
When you set up the initial synchronization project using the Launchpad, a default schedule for regular synchronization is created and assigned. Activate this schedule to synchronize on a regular basis.
To synchronize on a regular basis
-
In the Synchronization Editor, open the synchronization project.
-
Select the Configuration > Start up configurations category.
-
Select a start up configuration in the document view and click Edit schedule.
-
Edit the schedule properties.
-
To enable the schedule, click Activate.
- Click OK.
You can also start synchronization manually if there is no active schedule.
To start initial synchronization manually
-
In the Synchronization Editor, open the synchronization project.
-
Select the Configuration > Start up configurations category.
-
Select a start up configuration in the document view and click Run.
- Confirm the security prompt with Yes.
IMPORTANT: As long as a synchronization process is running, you must not start another synchronization process for the same target system. This especially applies, if the same synchronization objects would be processed.
-
If another synchronization process is started with the same start up configuration, the process is stopped and is assigned Frozen status. An error message is written to the One Identity Manager Service log file.
-
Starting another synchronization process with different start up configuration that addresses same target system may lead to synchronization errors or loss of data. Specify One Identity Manager behavior in this case, in the start up configuration.
Displaying synchronization results
Synchronization results are summarized in the synchronization log. You can specify the extent of the synchronization log for each system connection individually. One Identity Manager provides several reports in which the synchronization results are organized under different criteria.
To display a synchronization log
-
In the Synchronization Editor, open the synchronization project.
-
Select the Logs category.
-
Click in the navigation view toolbar.
Logs for all completed synchronization runs are displayed in the navigation view.
-
Select a log by double-clicking it.
An analysis of the synchronization is shown as a report. You can save the report.
To display a provisioning log
-
In the Synchronization Editor, open the synchronization project.
-
Select the Logs category.
-
Click in the navigation view toolbar.
Logs for all completed provisioning processes are displayed in the navigation view.
-
Select a log by double-clicking it.
An analysis of the provisioning is shown as a report. You can save the report.
The log is marked in color in the navigation view. This mark shows you the status of the synchronization/provisioning.
TIP: The logs are also displayed in the Manager under the <target system> > synchronization log category.
Related topics
Deactivating synchronization
Regular synchronization cannot be started until the synchronization project and the schedule are active.
To prevent regular synchronization
-
In the Synchronization Editor, open the synchronization project.
-
Select the start up configuration and deactivate the configured schedule.
Now you can only start synchronization manually.
An activated synchronization project can only be edited to a limited extend. The schema in the synchronization project must be updated if schema modifications are required. The synchronization project is deactivated in this case and can be edited again.
Furthermore, the synchronization project must be deactivated if synchronization should not be started by any means (not even manually).
To deactivate the synchronization project
-
In the Synchronization Editor, open the synchronization project.
-
Select the General view on the home page.
-
Click Deactivate project.
Detailed information about this topic
Synchronizing single objects
Individual objects can only be synchronized if the object is already present in the One Identity Manager database. The changes are applied to the mapped object properties. If a membership list belongs to one of these properties, the entries in the assignment table will also be updated.
NOTE: If the object is no longer present in the target system, then it is deleted from the One Identity Manager database.
To synchronize a single object
-
In the Manager, select the LDAP category.
-
Select the object type in the navigation view.
-
In the result list, select the object that you want to synchronize.
-
Select the Synchronize this object task.
A process for reading this object is entered in the job queue.
Features of synchronizing memberships
If you synchronize changes in an object's member list, run single object synchronization on the assignment's root object, The base table of an assignment contains an XDateSubItem column containing information about the last change to the memberships.
Example:
Base object for assigning user accounts to groups is the group.
In the target system, a user account was assigned to a group. To synchronize this assignment, in the Manager, select the group that the user account was assigned to and run single object synchronization. In the process, all of the group's memberships are synchronized.
The user account must already exist as an object in the One Identity Manager database for the assignment to be made.
Detailed information about this topic