サポートと今すぐチャット
サポートとのチャット

Identity Manager 9.0 LTS - Target System Synchronization Reference Guide

Target system synchronization with the Synchronization Editor Working with the Synchronization Editor Basics of target system synchronization Setting up synchronization
Starting the Synchronization Editor Creating a synchronization project Configuring synchronization
Setting up mappings Setting up synchronization workflows Connecting systems Editing the scope Using variables and variable sets Setting up start up configurations Setting up base objects
Overview of schema classes Customizing the synchronization configuration Checking the consistency of the synchronization configuration Activating the synchronization project Defining start up sequences
Running synchronization Synchronization analysis Setting up synchronization with default connectors Updating existing synchronization projects Script library for synchronization projects Additional information for experts Troubleshooting errors when connecting target systems Configuration parameters for target system synchronization Configuration file examples

Specifying the script language in synchronization projects

You can apply scripts at various points in the synchronization projectClosed; for example, when defining the schema properties, in the object filter, or when you define data operations for system connections through the generic database connectorClosed.

When you define a synchronization project with the project wizard, you specify a script language in which to create the script. You can select either C# or Visual Basic .NET. You can only use project templatesClosed in the synchronization wizard that support the selected script language.

NOTE: If you want to create a synchronization project using a template, check whether the project template supports the selected script language.

NOTE: You cannot change the script language once the project wizard is finished!

Create a new synchronization project to change the script language later.

Related topics

Templates for creating synchronization projects

Some system connectors provide templateClosed which you can use to configure a complete synchronization projectClosed with the project wizard, The project templatesClosed add the following components to the synchronization configuration in the synchronization project, depending on the target system type.

  • The scope
  • A start up configuration (without scheduleClosed)
  • The default variable set
  • A base object

    The synchronization base object, e.g. the actual Active Directory domain that you want to synchronize, is added as an object in the One Identity Manager database.

  • A synchronization workflowClosed for the initial import of the target system into the One Identity Manager database

    The workflow has the following characteristics:

    • Direction of synchronization is "One Identity Manager".
    • Processing methods in the synchronization steps are only defined in synchronization direction "One Identity Manager".
  • A provisioning workflowClosed

    This workflow is only created if the Read/write access to target system. ProvisioningClosed available. option is selected on the Restrict target system access page of the project wizard.

    The workflow has the following characteristics:

    • Synchronization in the direction of the "Target systemClosed".
    • Processing methods are only defined in the synchronization steps in synchronization direction "Target system".
    • Synchronization steps are only created for such schema classes whose schema types have write access.
  • The schema classes required
  • Mappings for all schema classes required

    These include:

    • Required virtual schema properties
    • Property mapping rules
    • Object matching rules

Also created is:

  • Operations for provisioning and single object synchronization

Once a synchronization project has been created from a project template, you can check the settings assign a schedule and start synchronization.

Restricting system access

When you set up a synchronization projectClosed with the project wizard, you decide whether the target system is only read in or whether One Identity Manager can also make changes. If you select the Target systemClosed has read-only access option, only modifications in the target system are transferred to the One Identity Manager database. Changes in the One Identity Manager database are not written to the target system. This means:

  • Direction of synchronization is "One Identity Manager".
  • The project wizard only creates one synchronization workflowClosed. A provisioning workflowClosed is not added.
  • Processing methods in the synchronization steps are only defined in synchronization direction "One Identity Manager".
Related topics

Configuring synchronization

Not all system connectors provide a project templateClosed for creating a full configured synchronization projectClosed. Therefore, you can also create a synchronization project manually. In this case, the project wizard sets up the system connection. All other synchronization configuration components must be configured after you have saved the synchronization project.

To manually set up synchronization of the One Identity Manager database with a target system

  1. Install and configure a synchronization serverClosed and declare the server as a Job server in One Identity Manager.
  2. Create a new synchronization project.
    • The project wizard sets up the system connection.
    • On the Select project template page, select Create blank project.
  1. Add mappings. Define property mapping rules and object matching rules.

  2. Create synchronization workflowsClosed.

  3. Create a start up configuration.

  4. Define the synchronization scope.

  5. Specify the base object of the synchronization.

  6. Specify the extent of the synchronization log.

  7. Run a consistency check.

  8. Activate the synchronization project.

  9. Save the new synchronization project in the database.

Detailed information about this topic
関連ドキュメント

The document was helpful.

評価を選択

I easily found the information I needed.

評価を選択