How to post-process outstanding objects

To post-process outstanding objects

  1. In the Manager, select the Data synchronization > Target system synchronization: <target system type> category.

    All tables assigned to the target system type are displayed in the navigation view.

  2. Select the table whose outstanding objects you want to edit in the navigation view.

    All objects marked as outstanding are shown on the form.

    TIP:

    To display object properties of an outstanding object

    1. Select the object on the target system synchronization form.

    2. Open the context menu and click Show object.

  1. Select the objects you want to rework. Multi-select is possible.

  2. Click on one of the following icons in the form toolbar to run the respective method.

    Table 9: Methods for handling outstanding objects

    Icon

    Method

    Description

    Delete

    The object is immediately deleted from the One Identity Manager database. Deferred deletion is not taken into account.

    Indirect memberships cannot be deleted.

    Publish

    The object is added to the target system. The Outstanding label is removed from the object.

    This runs a target system specific process that triggers the provisioning process for the object.

    Prerequisites:

    • The table containing the object can be published.

    • The target system connector has write access to the target system.

    Reset

    The Outstanding label is removed for the object.

  3. Confirm the security prompt with Yes.

NOTE: By default, the selected objects are processed in parallel, which speeds up the selected method. If an error occurs during processing, the action is stopped and all changes are discarded.

Bulk processing of objects must be disabled if errors are to be localized, which means the objects are processed sequentially. Failed objects are named in the error message. All changes that were made up until the error occurred are saved.

To disable bulk processing

  • Disable the icon in the form's toolbar.

Related topics

Troubleshooting

For detailed information about correcting errors during synchronization of object hierarchies, see the .One Identity Manager Target System Synchronization Reference Guide

Ignoring data error in synchronization

By default, objects with incorrect data are not synchronized. These objects can be synchronized once the data has been corrected. In certain situations, however, it might be necessary to synchronize objects like these and ignore the data properties that have errors. This synchronization behavior can be configured in One Identity Manager.

To ignoring data errors during synchronization in One Identity Manager

  1. In the Synchronization Editor, open the synchronization project.

  2. Select the Configuration > One Identity Manager connection category.

  3. In the General view, click Edit connection.

    This starts the system connection wizard.

  4. On the Additional options page, enable Try to ignore data errors.

    This option is only effective if Continue on error is set in the synchronization workflow.

    Default columns, such as primary keys, UID columns, or mandatory input columns cannot be ignored.

  5. Save the changes.

IMPORTANT: If this option is set, One Identity Manager tries to ignore commit errors that could be related to data errors in a single column. This causes the data changed in the affected column to be discarded and the object is subsequently saved again. This effects performance and leads to loss of data.

Only set this option in the exceptional circumstance of not being able to correct the data before synchronization.

Help for analyzing synchronization issues

You can generate a report for analyzing problems that arise during synchronization, inadequate performance for example. The report contains information such as:

  • Consistency check results

  • Revision filter settings

  • Scope applied

  • Analysis of the data store

  • Object access times in the One Identity Manager database and in the target system

To generate a synchronization analysis report

  1. In the Synchronization Editor, open the synchronization project.

  2. Select the Help > Generate synchronization analysis report menu item and click Yes in the security prompt.

    The report may take a few minutes to generate. It is displayed in a separate window.

  3. Print the report or save it in one of the available output formats.