지금 지원 담당자와 채팅
지원 담당자와 채팅

syslog-ng Store Box 7.4.0 - Packaging Checklist

Package contents inventory

Carefully unpack all server components from the packing cartons. The following items should be packaged with the syslog-ng Store Box:

  • A syslog-ng Store Box appliance, pre-installed with the latest syslog-ng Store Box firmware.

  • syslog-ng Store Box accessory kit, including the following:

    • syslog-ng Store Box 7.4.0 Packaging Checklist (this document).

    • GPL v2.0 license.

  • Rack mount hardware.

  • Power cable.

The default BIOS and IPMI passwords are in the documentation.

syslog-ng Store Box Hardware Installation Guide

This section describes how to set up the syslog-ng Store Box (SSB) hardware. Refer to the following documents for step-by-step instructions:

The manuals are also available online at the syslog-ng Store Box Documentation page. Note that SSB hardware is built to custom specifications: CPU, memory, network card, and storage options differ from the stock chassis. You can find the hardware specifications in Hardware specifications.

Installing the SSB hardware

The following section describes how to install a single syslog-ng Store Box (SSB) unit.

To install a single SSB unit

  1. Unpack SSB.

  2. Optional step: Install SSB into a rack with the slide rails. Slide rails are available for all SSB appliances.

  3. Connect the cables.

    1. For general networks:

      Connect the Ethernet cable facing your LAN to the Ethernet connector labeled 1. This is the external interface of SSB. This interface is used for the initial configuration of SSB, and for communication between SSB and the clients. (For details on the roles of the different interfaces, see Network interfaces.)

      For 10Gbit-only networks:

      Connect the cable facing your LAN to the SFP+ connector. This is the external interface of SSB, used for the initial configuration of SSB and for communication between SSB and the clients. For more information on the roles of the various interfaces, see Network interfaces.

      NOTE: For the list of compatible SFP+ peripherals for syslog-ng Store Box (SSB) Appliance 3500 outfitted with Intel Ethernet Converged Network Adapter X520-DA2 NIC, refer to the Intel Product Compatibility Tool.

      For the list of compatible SFP+ peripherals for syslog-ng Store Box (SSB) Appliance 3500 outfitted with Broadcom NetXtreme-E Series P210P 2x10G PCIe NIC, see Supported Cables for Broadcom Ethernet Network Adapters in the Broadcom Ethernet Network Adapter User Guide.

      NOTE: For the list of compatible SFP+ peripherals for syslog-ng Store Box (SSB) Appliance 4000 outfitted with Broadcom NetXtreme-E Series P210P 2x10G PCIe NIC, see Supported Cables for Broadcom Ethernet Network Adapters in the Broadcom Ethernet Network Adapter User Guide.

      Caution:

      Do not leave any unused SFP/SFP+ transceiver in the 10Gbit interface. It may cause network outage.

    2. Connect an Ethernet cable that you can use to remotely support the SSB hardware to the IPMI interface of SSB. For details, see the following documents:

      For syslog-ng Store Box (SSB) Appliance 3000, 3500 and 4000, see Knowledge Base Article Latest IPMI firmware for Syslog-ng Store Box 3000/3500/4000 and One Identity Safeguard for Privileged Sessions 3000/3500/4000 appliances.

      Caution:

      Connect the IPMI before plugging in the power cord. Failing to do so will result in IPMI failure.

      Caution: SECURITY HAZARD!

      The IPMI interface, like all out-of-band management interfaces, has known vulnerabilities that One Identity cannot fix or have an effect on. To avoid security hazards, One Identity recommends that you only connect the IPMI interface to well-protected, separated management networks with restricted accessibility. Failing to do so may result in an unauthorized access to all data stored on the SSB appliance. Data on the appliance can be unencrypted or encrypted, and can include sensitive information, for example, passwords, decryption keys, private keys, and so on.

      For more information, see Best Practices for managing servers with IPMI features enabled in Datacenters.

      NOTE: The administrator of SSB must be authorized and able to access the IPMI interface for support and troubleshooting purposes in case vendor support is needed.

      The following ports are used by the IPMI interface:

      • Port 623 (UDP): IPMI (cannot be changed)

      • Port 5123 (UDP): floppy (cannot be changed)

      • Port 5901 (TCP): video display (configurable)

      • Port 5900 (TCP): HID (configurable)

      • Port 5120 (TCP): CD (configurable)

      • Port 80 (TCP): HTTP (configurable)

    3. (Optional) Connect the Ethernet cable to be used for managing SSB after its initial configuration to the Ethernet connector labeled 2. This is the management interface of SSB. For more information about the different interfaces, see Network interfaces.

    4. (Optional) Connect the Ethernet cable connecting SSB to another SSB node to the Ethernet connector labeled 4. This is the high availability (HA) interface of SSB. For more information about the roles of the different interfaces, see Network interfaces.

  4. Power on the hardware.

  5. Change the BIOS password on the syslog-ng Store Box. The default password is ADMIN or changeme, depending on your hardware.

  6. Change the IPMI password on the syslog-ng Store Box. The default password is ADMIN or changeme, depending on your hardware.

    NOTE:Ensure that you have the latest version of IPMI firmware installed. You can download the relevant firmware from the One Identity Knowledge Base:

    For syslog-ng Store Box (SSB) Appliance 3000, 3500 and 4000, see Knowledge Base Article Latest IPMI firmware for Syslog-ng Store Box 3000/3500/4000 and One Identity Safeguard for Privileged Sessions 3000/3500/4000 appliances.

    To change the IPMI password, connect to the IPMI remote console.

    NOTE: If you encounter issues when connecting to the IPMI remote console, add the DNS name or the IP address of the IPMI interface to the allow list of the Java console. For more information, see How can I configure the Exception Site List? in the Java documentation.

  7. Following boot, SSB attempts to receive an IP address automatically via DHCP. If it fails to obtain an automatic IP address, it starts listening for HTTPS connections on the 192.168.1.1 IP address.

    To configure SSB to listen for connections on a custom IP address, complete the following steps:

    1. Access SSB from the local console, and log in with username root and password default.

    2. In the Console Menu, select Shells > Core shell.

    3. Change the IP address of SSB:

      ip addr add <IP-address>/24 dev eth0

      Replace <IP-address> with an IPv4 address suitable for your environment.

    4. Set the default gateway using the following command:

      ip route add default via <IP-of-default-gateway>

      Replace <IP-of-default-gateway> with the IP address of the default gateway.

    5. Type exit, then select Logout from the Console Menu.

  8. Connect to the SSB web interface from a client machine and complete the Welcome Wizard as described in The Welcome Wizard and the first login.

    NOTE: The syslog-ng Store Box Administration Guide is available on the syslog-ng Store Box Documentation page.

Installing two SSB units in HA mode

The following describes how to install SSB with high availability support.

To install SSB with high availability support

  1. For the first SSB unit, complete Installing the SSB hardware.

  2. For the second SSB unit, complete Steps 1-3 of Installing the SSB hardware.

  3. Connect the two units with an Ethernet cable via the Ethernet connectors labeled as 4.

  4. Power on the second unit.

  5. Change the BIOS and IPMI passwords on the second unit. The default password is ADMIN or changeme, depending on your hardware.

  6. Connect to the SSB web interface of the first unit from a client machine and enable high availability mode. Navigate to Basic Settings > High Availability . Click Convert to Cluster, then reload the page in your browser.

  7. Click Reboot Cluster.

  8. Wait until the slave unit synchronizes its disk to the master unit. Depending on the size of the hard disks, this may take several hours. You can increase the speed of the synchronization via the SSB web interface at Basic Settings > High Availability > DRBD sync rate limit.

셀프 서비스 도구
지식 기반
공지 및 알림
제품 지원
소프트웨어 다운로드
기술 설명서
사용자 포럼
비디오 자습서
RSS 피드
문의처
라이센싱 지원가져오기
기술 지원
모두 보기
관련 문서

The document was helpful.

평가 결과 선택

I easily found the information I needed.

평가 결과 선택