The connection wizard is missing when specifying a history database
说明
When attempting to configure a new History Database for version 9.0LTS, the entry in Designer for the option 'Connection Parameter (Transport)' does not provide an ability to enter a connection string. The three dots menu is missing and the database connection string must be entered in manually.
Please note that this only affects version 9.0 LTS.
原因
This feature was only added to Identity Manager 9.1 non LTS and above.
解决办法
WORKAROUND
Use the steps below to workaround the issue:
1. Open Object Browser and login with an applicable account
2. Click on DialogHistoryDB
3. Click on the entry listed
4. Click on the ConnectionString column
5. Copy the data
6. Place the data in the TransportConnectionString column
7. Save the changes
STATUS
This will not be added to the 9.0 LTS version of Identity Manager.