立即与支持人员聊天
与支持团队交流

Identity Manager 8.1.4 - Target System Synchronization Reference Guide

Target system synchronization with the Synchronization Editor Working with the Synchronization Editor Basics of target system synchronization Setting up synchronization
Starting the Synchronization Editor Creating a synchronization project Configuring synchronization
Setting up mappings Setting up synchronization workflows Connecting systems Editing the scope Using variables and variable sets Setting up start up configurations Setting up base objects
Overview of schema classes Customizing the synchronization configuration Checking the consistency of the synchronization configuration Activating the synchronization project Defining start up sequences
Running synchronization Synchronization analysis Setting up synchronization with default connectors Updating existing synchronization projects Script library for synchronization projects Additional information for experts Resolving errors when connecting target systems Configuration parameters for target system synchronization Configuration file examples Glossary

Variable properties

NOTE: Variable labeled as system variables cannot be modified.

Enter the following properties for a variable in the default variable set.

Table 59: Variable properties
Property Description
Name Variable name. The name must be unique within a variable set.
Display name Display name of the variable.
Value Default value of the variable.
  • To display and edit the value of a hierarchy filterClosed, click Edit....
  • To display and edit the script of a script variable, click Edit....
Secret value Specifies whether the variable in the Synchronization EditorClosed may be displayed.

If this option is set, the value is not displayed.

In use Specifies whether the variable is used in a Synchronization Editor function.
Description Text field for additional explanation.

To show all definition used in a variable set

  1. Select a variable in the default variable set.
  2. Click in the toolbar.

To restore a variable's default value in a specialized variable set

  1. Select a variable in the specialized variable set.
  2. Click in the toolbar.
Related topics

Using scripts in variables

You can write scripts for finding variable values. You can use scripts, for example, for reading a system user's password from an external password management system.

NOTE: The External password management option must be set for a system user in order to use their password from an external password management system. For detailed information about editing system users, see the One Identity Manager Authorization and Authentication Guide.

To create a script variable.

  1. Create the variable in the default variable set.
  2. Select the variable and click in the toolbar.
  3. In the Value input field, click Edit.
  4. Enter the script and click OK.
  5. Save the changes.

In this way, you can convert existing variables into script variables.

To convert script variables into simple variables.

  1. Select the script variable in the default variable set.
  2. Click in the toolbar.
  3. Confirm the security prompt with Yes.
Related topics

Setting up start up configurations

A start up configuration contains all the required properties and options for a tangible synchronizationClosed. This specifies which synchronization configuration components (workflows, mappingsClosed, variable sets) should be used for synchronization. Synchronization is started with a schedule. Different start up configurations can be set up for different synchronization targets.

If the synchronization projectClosed was creating using a default project templateClosed, a start up configuration is added. You can edit this start up configuration and create new start up configurations. If the synchronization project was created without a project template, start up configuration is set up.

How to create start up configurations

To create a start up configuration

  1. In the Synchronization EditorClosed, select the Configuration | Start up configurations category.
  2. Click in the document view toolbar.
  3. Edit the start up configuration's master data.
  4. Click OK.
相关文档

The document was helpful.

选择评级

I easily found the information I needed.

选择评级