サポートと今すぐチャット
サポートとのチャット

Identity Manager 9.0 LTS - Administration Guide for Connecting to a Universal Cloud Interface

Managing Universal Cloud Interface environments Synchronizing a cloud application in the Universal Cloud Interface
Setting up initial synchronization with a cloud application in the Universal Cloud Interface Customizing the synchronization configuration Running synchronization Tasks following synchronization Troubleshooting Ignoring data error in synchronization Pausing handling of target system specific processes (Offline mode)
Provisioning object changes Managing cloud user accounts and employees Managing assignments of cloud groups and system entitlements Login information for cloud user accounts Mapping cloud objects in One Identity Manager
Cloud target systems Container structures Cloud user accounts Cloud groups Cloud system entitlements Cloud permissions controls Reports about objects in cloud target systems
Handling cloud objects in the Web Portal Basic data for managing a Universal Cloud Interface environment Configuration parameters for managing cloud target systems Default project template for cloud applications in the Universal Cloud Interface

Troubleshooting

Synchronization Editor helps you to analyze and eliminate synchronization errors.

  • Simulating synchronization

    The simulation allows you to estimate the result of synchronization. This means you can, for example, recognize potential errors in the synchronization configuration.

  • Analyzing synchronization

    You can generate the synchronization analysis report for analyzing problems which occur during synchronization, for example, insufficient performance.

  • Logging messages

    One Identity Manager offers different options for logging errors. These include the synchronization log, the log file for One Identity Manager Service, the logging of messages with NLOG, and similar.

  • Reset start information

    If synchronization stopped unexpectedly, for example, because a server was not available, the start information must be reset manually. Only then can the synchronization be restarted.

For more information about these topics, see the One Identity Manager Target System Synchronization Reference Guide.

Related topics

Ignoring data error in synchronization

By default, objects with incorrect data are not synchronized. These objects can be synchronized once the data has been corrected. In certain situations, however, it might be necessary to synchronize objects like these and ignore the data properties that have errors. This synchronization behavior can be configured in One Identity Manager.

To ignoring data errors during synchronization in One Identity Manager

  1. In the Synchronization Editor, open the synchronization project.

  2. Select the Configuration > One Identity Manager connection category.

  3. In the General view, click Edit connection.

    This starts the system connection wizard.

  4. On the Additional options page, enable Try to ignore data errors.

    This option is only effective if Continue on error is set in the synchronization workflow.

    Default columns, such as primary keys, UID columns, or mandatory input columns cannot be ignored.

  5. Save the changes.

IMPORTANT: If this option is set, One Identity Manager tries to ignore commit errors that could be related to data errors in a single column. This causes the data changed in the affected column to be discarded and the object is subsequently saved again. This effects performance and leads to loss of data.

Only set this option in the exceptional circumstance of not being able to correct the data before synchronization.

Pausing handling of target system specific processes (Offline mode)

If a target system connector is not able to reach the target system temporarily, you can enable offline mode for the target system. This stops target system specific processes from being frozen and having to be manually re-enabled later.

Whether offline mode is generally available for a target system connection is set in the base object of the respective synchronization project. Once a target system is truly unavailable, the target system connection can be switched offline and online again with the Launchpad.

In offline mode, all Job servers assigned to the base object are stopped. This includes the synchronization server and all Job servers involved in load balancing. If one of the Job servers also handles other tasks, these are not processed either.

Prerequisites

Offline mode can only be specified for a base object if certain prerequisites are fulfilled.

  • The synchronization server is not used for any other base object as a synchronization server.

  • If a server function is assigned to the base object, none of the Job servers with this server function may have any other server function (for example, update server).

  • A dedicated synchronization server must be set up to exclusively process the Job queue for this base object. The same applies to all Job servers that are determined by the server function.

To allow offline mode for a base object

  1. In the Synchronization Editor, open the synchronization project.

  2. Select the Base objects category.

  3. Select a base object in the document view and click .

  4. Enable Offline mode available.

  5. Click OK.
  6. Save the changes.

IMPORTANT: To prevent data inconsistencies, the offline phase should be kept as short as possible.

The number of processes to handle depends on the extent of the changes in the One Identity Manager database and their effect on the target system during the offline phase. To establish data consistency between the One Identity Manager database and the target system, all pending processes must be handled before synchronization can start.

Only use offline mode, if possible, for short system downtimes such as maintenance windows.

To flag a target system as offline

  1. Start the Launchpad and log in on the One Identity Manager database.

  2. Select Manage > System monitoring > Flag target systems as offline.

  3. Click Run.

    This opens the Manage offline systems dialog. The Base objects section displays the base objects of target system connections that can be switched to offline.

  4. Select the base object whose target system connection is not available.

  5. Click Switch offline.

  6. Confirm the security prompt with OK.

    This stops all the Job servers assigned to the base object. No more synchronization or provisioning Jobs are performed. The Job Queue Info program shows when a Job server has been switched offline and the corresponding tasks are not being processed.

For more information about offline mode, see the One Identity Manager Target System Synchronization Reference Guide.

Related topics

Provisioning object changes

Changes to cloud objects can only be made in the Cloud Systems Management Module. Provisioning processes ensure that object changes are transferred from the Cloud Systems Management Module into the Universal Cloud Interface Module. By default, these object changes are then published in the cloud application by automatic provisioning processes.

One Identity Manager logs the object changes as pending changes in separate tables. The QBMPendingChange table contains the modified objects and their processing status. The details of the changes, operations to run, time stamp and processing status are saved in the QBMPendingChangeDetail table.

The processing status of an object is not set to successful until all associated changes for this object have been successfully provisioned. An object's processing status is set as failed if all associated changes have been processed and at least one them has failed.

Detailed information about this topic
関連ドキュメント

The document was helpful.

評価を選択

I easily found the information I needed.

評価を選択