지금 지원 담당자와 채팅
지원 담당자와 채팅

Identity Manager 9.2 - Target System Synchronization Reference Guide

Target system synchronization with the Synchronization Editor Working with the Synchronization Editor Basics of target system synchronization Setting up synchronization
Starting the Synchronization Editor Creating a synchronization project Configuring synchronization
Setting up mappings Setting up synchronization workflows Connecting systems Configuring the synchronization log Editing the scope Using variables and variable sets Setting up start up configurations Setting up base objects
Overview of schema classes Customizing the synchronization configuration Checking the consistency of the synchronization configuration Activating the synchronization project Defining start up sequences Copying synchronization projects
Running synchronization Synchronization analysis Setting up synchronization with default connectors Updating existing synchronization projects Script library for synchronization projects Additional information for experts Troubleshooting errors when connecting target systems Configuration parameters for target system synchronization Configuration file examples

How to delete base objects

To delete a base object

  1. Select the Configuration > Base objects category.
  2. Select a base object in the document view and click .
  3. Confirm the security prompt with Yes.

Properties of base objects

Enter the following properties for a base object.

Table 64: Properties of base objects

Property

Description

SynchronizationClosed has no base object

Defines whether a specific base object is required for synchronization.

If this option is set, a specific object cannot be selected from the base table.

Base table

Select the table from which to select the base object, for example, ADSDomain.

Base objectClosed

Select the object from the base table formed by the base object for synchronization and provisioning processes.

Synchronization server

Select the synchronization serverClosed.

Server functionClosed

The server’s server function that synchronizes Single object synchronization and provisioning types. This allows parallel editing. If no server function is given, the synchronization server handles these processes.

Assign a customClosed server function.

Variable setClosed

Select the variable set that contains the connection parameter which corresponds with the base object. Variables from selected variable sets are displayed.

For each base objects there must be a start up configuration, which uses the same variable set.

Offline mode available

Specifies whether the target system can be flagged as temporarily offline. This makes it possible to respond to short-term system outages.

Related topics

Overview of schema classes

Synchronization EditorClosed displays a schema overview for each system connection. The schema overview contains all schema types and the derived schema classes used in the synchronization projectClosed. You can edit schema classes here.

To display the schema overview

  1. Edit the system connection properties.

    For more information, see How to edit system connection properties.

  2. Open the SchemaClosed classes view.

    This displays the schema type and schema class structures.

How to add schema classes

To create a schema class

  1. Edit the system connection properties.

    For more information, see How to edit system connection properties.

  2. Open the SchemaClosed classes view.
  3. Click in the schema overview menu bar.
  4. Edit the schema class properties.

    For more information, see Schema class properties.

  5. Save the changes.

To create a new mapping for a schema class

  1. Create a new mapping.

    For more information, see Creating mappings.

  2. Select One IdentityClosed Manager schema class or Target system schemaClosed class.
  3. Click .
  4. Edit the schema class properties.

    For more information, see Schema class properties.

  5. Save the changes.
관련 문서

The document was helpful.

평가 결과 선택

I easily found the information I needed.

평가 결과 선택