The python() and python-fetcher() drivers have the following options.
Type: | string |
Default: | N/A |
Description: The name of the Python class that implements the source, for example:
python( class("MyPythonSource") );
If you want to store the Python code in an external Python file, the class() option must include the name of the Python file containing the class, without the path and the .py extension, for example:
python( class("MyPythonfilename.MyPythonSource") );
For details, see Python code in external files
Type: | integer [seconds] |
Default: | -1 (disabled) |
Description: If the fetch method of a python-fetcher() source returns with the LogFetcher.FETCH_NO_DATA constant, the source waits time-reopen() seconds before calling the fetch method again. If you want to call the fetch method sooner, set the fetch-no-data-delay() option to the number of seconds to wait before calling the fetch method.
Type: | assume-utf8, empty-lines, expect-hostname, kernel, no-hostname, no-multi-line, no-parse, sanitize-utf8, store-legacy-msghdr, store-raw-message, syslog-protocol, validate-utf8 |
Default: | empty set |
Description: Specifies the log parsing options of the source.
assume-utf8: The assume-utf8 flag assumes that the incoming messages are UTF-8 encoded, but does not verify the encoding. If you explicitly want to validate the UTF-8 encoding of the incoming message, use the validate-utf8 flag.
empty-lines: Use the empty-lines flag to keep the empty lines of the messages. By default, syslog-ng OSE removes empty lines automatically.
expect-hostname: If the expect-hostname flag is enabled, syslog-ng OSE will assume that the log message contains a hostname and parse the message accordingly. This is the default behavior for TCP sources. Note that pipe sources use the no-hostname flag by default.
guess-timezone: Attempt to guess the timezone of the message if this information is not available in the message. Works when the incoming message stream is close to real time, and the timezone information is missing from the timestamp.
kernel: The kernel flag makes the source default to the LOG_KERN | LOG_NOTICE priority if not specified otherwise.
no-hostname: Enable the no-hostname flag if the log message does not include the hostname of the sender host. That way syslog-ng OSE assumes that the first part of the message header is ${PROGRAM} instead of ${HOST}. For example:
source s_dell { network( port(2000) flags(no-hostname) ); };
no-multi-line: The no-multi-line flag disables line-breaking in the messages: the entire message is converted to a single line. Note that this happens only if the underlying transport method actually supports multi-line messages. Currently the file() and pipe() drivers support multi-line messages.
no-parse: By default, syslog-ng OSE parses incoming messages as syslog messages. The no-parse flag completely disables syslog message parsing and processes the complete line as the message part of a syslog message. The syslog-ng OSE application will generate a new syslog header (timestamp, host, and so on) automatically and put the entire incoming message into the MESSAGE part of the syslog message (available using the ${MESSAGE} macro). This flag is useful for parsing messages not complying to the syslog format.
If you are using the flags(no-parse) option, then syslog message parsing is completely disabled, and the entire incoming message is treated as the ${MESSAGE} part of a syslog message. In this case, syslog-ng OSE generates a new syslog header (timestamp, host, and so on) automatically. Note that since flags(no-parse) disables message parsing, it interferes with other flags, for example, disables flags(no-multi-line).
dont-store-legacy-msghdr: By default, syslog-ng stores the original incoming header of the log message. This is useful if the original format of a non-syslog-compliant message must be retained (syslog-ng automatically corrects minor header errors, for example, adds a whitespace before msg in the following message: Jan 22 10:06:11 host program:msg). If you do not want to store the original header of the message, enable the dont-store-legacy-msghdr flag.
sanitize-utf8: When using the sanitize-utf8 flag, syslog-ng OSE converts non-UTF-8 input to an escaped form, which is valid UTF-8.
store-raw-message: Save the original message as received from the client in the ${RAWMSG} macro. You can forward this raw message in its original form to another syslog-ng node using the syslog-ng() destination, or to a SIEM system, ensuring that the SIEM can process it. Available only in
syslog-protocol: The syslog-protocol flag specifies that incoming messages are expected to be formatted according to the new IETF syslog protocol standard (RFC5424), but without the frame header. Note that this flag is not needed for the syslog driver, which handles only messages that have a frame header.
validate-utf8: The validate-utf8 flag enables encoding-verification for messages formatted according to the new IETF syslog standard (for details, see IETF-syslog messages). If the
The flags and the hostname-related options (for example, use-dns) set in the configuration file influence the behavior of the LogMessage.parse() method of the Python source. They have no effect if you set the message or the hostname directly, without using LogMessage.parse().
Type: | yes or no |
Default: | no |
Description: Enable or disable hostname rewriting.
If enabled (keep-hostname(yes)), syslog-ng OSE assumes that the incoming log message was sent by the host specified in the HOST field of the message.
If disabled (keep-hostname(no)), syslog-ng OSE rewrites the HOST field of the message, either to the IP address (if the use-dns() parameter is set to no), or to the hostname (if the use-dns() parameter is set to yes and the IP address can be resolved to a hostname) of the host sending the message to syslog-ng OSE. For details on using name resolution in syslog-ng OSE, see Using name resolution in syslog-ng.
s
|
NOTE:
If the log message does not contain a hostname in its HOST field, syslog-ng OSE automatically adds a hostname to the message.
|
This option can be specified globally, and per-source as well. The local setting of the source overrides the global option if available.
|
NOTE:
When relaying messages, enable this option on the syslog-ng OSE server and also on every relay, otherwise syslog-ng OSE will treat incoming messages as if they were sent by the last relay. |
Type: | number |
Default: | 100 |
Description: The size of the initial window, this value is used during flow-control. Its value cannot be lower than 100, unless the dynamic-window-size() option is enabled. For details on flow-control, see Managing incoming and outgoing messages with flow-control.
Type: | list of python modules |
Default: | empty list |
Description: The syslog-ng OSE application imports Python modules specified in this option, before importing the code of the Python class. This option has effect only when the Python class is provided in an external Python file. This option has no effect when the Python class is provided within the syslog-ng OSE configuration file (in a python{} block). You can use the loaders() option to modify the import mechanism that imports Python class. For example, that way you can use hy in your Python class.
python(class(usermodule.HyParser) loaders(hy))
Type: | string |
Default: | N/A |
Description: This option allows you to pass custom values from the configuration file to the Python code. Enclose both the option names and their values in double-quotes. The Python code will receive these values during initialization as the options dictionary. For example, you can use this to set the IP address of the server from the configuration file, so it is not hard-coded in the Python object.
python( class("MyPythonClass") options( "host" "127.0.0.1" "port" "1883" "otheroption" "value") );
For example, you can refer to the value of the host field in the Python code as options["host"]. Note that the Python code receives the values as strings, so you might have to cast them to the type required, for example: int(options["port"])
Type: | string |
Default: |
Description:If you receive the following error message during syslog-ng OSE startup, set the persist-name() option of the duplicate drivers:
Error checking the uniqueness of the persist names, please override it with persist-name option. Shutting down.
This error happens if you use identical drivers in multiple sources, for example, if you configure two file sources to read from the same file. In this case, set the persist-name() of the drivers to a custom string, for example, persist-name("example-persist-name1").
Type: | string |
Default: |
Description: Label the messages received from the source with custom tags. Tags must be unique, and enclosed between double quotes. When adding multiple tags, separate them with comma, for example tags("dmz", "router"). This option is available only in syslog-ng 3.1 and later.
Type: | name of the timezone, or the timezone offset |
Default: |
Description: The default timezone for messages read from the source. Applies only if no timezone is specified within the message itself.
The timezone can be specified by using the name, for example, time-zone("Europe/Budapest")), or as the timezone offset in +/-HH:MM format, for example, +01:00). On Linux and UNIX platforms, the valid timezone names are listed under the /usr/share/zoneinfo directory.
|
Caution:
This option is available only when using Python 3. |
The Python source allows you to write your own source in Python. You can import external Python modules to receive or fetch the messages. Since many services have a Python library, the Python source makes integrating syslog-ng OSE very easy and quick.
You can write two different type of sources in Python:
Server-style sources that receives messages. Write server-style sources if you want to use an event-loop based, nonblocking server framework in Python, or if you want to implement a custom loop.
Fetcher-style sources that actively fetch messages. In general, write fetcher-style sources (for example, when using simple blocking APIs), unless you explicitly need a server-style source.
This section describes fetcher-style sources. For details on server-style sources, see python: writing server-style Python sources.
The following points apply to using Python blocks in syslog-ng OSE in general.
Python parsers and template functions are available in syslog-ng OSE version
Python destinations and sources are available in syslog-ng OSE version
Supported Python versions: 2.7
The Python block must be a top-level block in the syslog-ng OSE configuration file.
If you store the Python code in a separate Python file and only include it in the syslog-ng OSE configuration file, make sure that the PYTHON_PATH environment variable includes the path to the Python file, and export the PYTHON_PATH environment variable. For example, if you start syslog-ng OSE manually from a terminal and you store your Python files in the /opt/syslog-ng/etc directory, use the following command: export PYTHONPATH=/opt/syslog-ng/etc
In production, when syslog-ng OSE starts on boot, you must configure your startup script to include the Python path. The exact method depends on your operating system. For recent Red Hat Enterprise Linux, Fedora, and CentOS distributions that use systemd, the systemctl command sources the /etc/sysconfig/syslog-ng file before starting syslog-ng OSE. (On openSUSE and SLES, /etc/sysconfig/syslog file.) Append the following line to the end of this file: PYTHONPATH="<path-to-your-python-file>", for example, PYTHONPATH="/opt/syslog-ng/etc"
The Python object is initiated every time when syslog-ng OSE is started or reloaded.
The Python block can contain multiple Python functions.
Using Python code in syslog-ng OSE can significantly decrease the performance of syslog-ng OSE, especially if the Python code is slow. In general, the features of syslog-ng OSE are implemented in C, and are faster than implementations of the same or similar features in Python.
Validate and lint the Python code before using it. The syslog-ng OSE application does not do any of this.
Python error messages are available in the internal() source of syslog-ng OSE.
You can access the name-value pairs of syslog-ng OSE directly through a message object or a dict.
To help debugging and troubleshooting your Python code, you can send log messages to the internal() source of syslog-ng OSE. For details, see Logging from your Python code.
Python sources consist of two parts. The first is a syslog-ng OSE source object that you define in your syslog-ng OSE configuration and use in the log path. This object references a Python class, which is the second part of the Python source. The Python class receives or fetches the log messages, and can do virtually anything that you can code in Python. You can either embed the Python class into your syslog-ng OSE configuration file, or store it in an external Python file.
source <name_of_the_python_source>{ python-fetcher( class("<name_of_the_python_class_executed_by_the_source>") ); }; python { from syslogng import LogFetcher from syslogng import LogMessage class <name_of_the_python_class_executed_by_the_source>(LogFetcher): def init(self, options): # optional print("init") print(options) return True def deinit(self): # optional print("deinit") def open(self): # optional print("open") return True def fetch(self): # mandatory print("fetch") # return LogFetcher.FETCH_ERROR, # return LogFetcher.FETCH_NOT_CONNECTED, # return LogFetcher.FETCH_TRY_AGAIN, # return LogFetcher.FETCH_NO_DATA, return LogFetcher.FETCH_SUCCESS, msg def request_exit(self): print("request_exit") # If your fetching method is blocking, do something to break it # For example, if it reads a socket: socket.shutdown() def close(self): # optional print("close") };
Fetcher-style Python sources must be inherited from the syslogng.LogFetcher class, and must implement at least the fetch method. Multiple inheritance is allowed, but only for pure Python super classes.
For fetcher-style Python sources, syslog-ng OSE handles the event loop and the scheduling automatically. You can use simple blocking server/client libraries to receive or fetch logs.
You can retrieve messages using the fetch() method.
The syslog-ng OSE application initializes Python objects every time when it is started or reloaded. The init method is executed as part of the initialization. You can perform any initialization steps that are necessary for your source to work.
When this method returns with False, syslog-ng OSE does not start. It can be used to check options and return False when they prevent the successful start of the source.
options: This optional argument contains the contents of the options() parameter of the syslog-ng OSE configuration object as a Python dict.
The open(self) method opens the resources required for the source, for example, it initiates a connection to the target service. It is called after init() when syslog-ng OSE is started or reloaded. If fetch() returns with an error, syslog-ng OSE calls the close() and open() methods before trying to fetch a new message.
If open() fails, it should return the False value. In this case, syslog-ng OSE retries it every time-reopen() seconds. By default, this is 1 second for Python sources and destinations, the value of time-reopen() is not inherited from the global option. For details, see python-fetcher: writing fetcher-style Python sources.
Use the fetch method to fetch messages and pass them to the log paths.
For details on parsing messages, see Python LogMessage API.
The fetch method must return one of the following values:
LogFetcher.FETCH_ERROR: Fetching new messages failed, syslog-ng OSE calls the close and open methods.
LogFetcher.FETCH_NO_DATA: There was not any data available. The source waits before calling the fetch method again. The wait time is equal to time-reopen() by default, but you can override it by setting the fetch-no-data-delay() option in the source.
LogFetcher.FETCH_NOT_CONNECTED: Could not access the source, syslog-ng OSE calls the open method.
LogFetcher.FETCH_SUCCESS, msg: Post the message returned as the second argument.
LogFetcher.FETCH_TRY_AGAIN: The fetcher could not provide a message this time, but will make the source call the fetch method as soon as possible.
If you use blocking operations within the fetch() method, use request_exit() to interrupt those operations (for example, to shut down a socket), otherwise syslog-ng OSE is not able to stop. Note that syslog-ng OSE calls the request_exit method from a thread different from the source thread.
Close the connection to the target service. Usually it is called right before deinit() when stopping or reloading syslog-ng OSE. It is also called when fecth() fails.
This method is executed when syslog-ng OSE is stopped or reloaded. This method does not return a value.
For the list of available optional parameters, see python() and python-fetcher() source options.
Using the snmptrap() source, you can read and parse the SNMP traps of the Net-SNMP's snmptrapd application. syslog-ng OSE can read these traps from a log file, and extract their content into name-value pairs, making it easy to forward them as a structured log message (for example, in JSON format). The syslog-ng OSE application automatically adds the .snmp. prefix to the name of the fields the extracted from the message.
The snmptrap() source is available in syslog-ng OSE version
The snmptrap() source has only the options listed in snmptrap() source options. Other options commonly available in other source drivers are not supported.
In addition to traps, the log of snmptrapd may contain other messages (for example, daemon start/stop information, debug logs) as well. Currently syslog-ng OSE discards these messages.
The syslog-ng OSE application cannot resolve OIDs, you have to configure snmptrapd to do so. Note that because of a bug, if snmptrapd does not escape String values in the VarBindList if it can resolve an OID to a symbolic name. As a result, syslog-ng OSE cannot process traps that contain the = in the value of the string. To overcome this problem, disable resolving OIDs in snmptrapd. For details, see the documentation of snmptrapd.
The colon (:) character is commonly used in SNMP traps. However, this character cannot be used in the name of syslog-ng OSE macros (name-value pairs). Therefore, the syslog-ng OSE application automatically replaces all consecutive : characters with a single underscore (_) character. For example, you can reference the value of the NET-SNMP-EXAMPLES-MIB::netSnmpExampleString key using the ${NET-SNMP-EXAMPLES-MIB_netSnmpExampleString} macro.
Note that this affects only name-value pairs (macros). The generated message always contains the original name of the key.
Configure snmptrapd to log into a file.
If you use SMIv1 traps, include the following format string in the configuration file of snmptrapd:
format1 %.4y-%.2m-%.2l %.2h:%.2j:%.2k %B [%b]: %N\n\t%W Trap (%q) Uptime: %#T\n%v\n
If you use SMIv2 traps, use the default format. The snmptrap() source of syslog-ng OSE expects this default format:
format2 %.4y-%.2m-%.2l %.2h:%.2j:%.2k %B [%b]:\n%v\n
Beacause of an snmptrapd bug, if you specify the filename in the configuration file with logOption, you must also specify another output as a command line argument (-Lf, -Ls). Otherwise, snmptrapd will not apply the the trap format.
To use the snmptrap() driver, the scl.conf file must be included in your syslog-ng OSE configuration:
@include "scl.conf"
A sample snmptrapd configuration:
authCommunity log,execute,net public format1 %.4y-%.2m-%.2l %.2h:%.2j:%.2k %B [%b]: %N\n\t%W Trap (%q) Uptime: %#T\n%v\n outputOption s
Starting snmptrapd: snmptrapd -A -Lf /var/log/snmptrapd.log
Sending a sample V2 trap message: snmptrap -v2c -c public 127.0.0.1 666 NET-SNMP-EXAMPLES-MIB::netSnmpExampleHeartbeatNotification netSnmpExampleHeartbeatRate i 60 netSnmpExampleString s "string". From this trap, syslog-ng OSE receives the following input:
2017-05-23 15:29:40 localhost [UDP: [127.0.0.1]:59993->[127.0.0.1]:162]: SNMPv2-SMI::mib-2.1.3.0 = Timeticks: (666) 0:00:06.66 SNMPv2-SMI::snmpModules.1.1.4.1.0 = OID: NET-SNMP-EXAMPLES-MIB::netSnmpExampleHeartbeatNotification NET-SNMP-EXAMPLES-MIB::netSnmpExampleHeartbeatRate = INTEGER: 60 NET-SNMP-EXAMPLES-MIB::netSnmpExampleString = STRING: string
The following syslog-ng OSE configuration sample uses the default settings of the driver, reading SNMP traps from the /var/log/snmptrapd.log file, and writes the log messages generated from the traps into a file.
@include "scl.conf" log { source { snmptrap(filename("/var/log/snmptrapd.log")); }; destination { file("/var/log/example.log"); }; };
From the trap, syslog-ng OSE writes the following into the log file:
May 23 15:29:40 myhostname snmptrapd: hostname='localhost', transport_info='UDP: [127.0.0.1]:59993->[127.0.0.1]:162', SNMPv2-SMI::mib-2.1.3.0='(666) 0:00:06.66', SNMPv2-SMI::snmpModules.1.1.4.1.0='NET-SNMP-EXAMPLES-MIB::netSnmpExampleHeartbeatNotification', NET-SNMP-EXAMPLES-MIB::netSnmpExampleHeartbeatRate='60', NET-SNMP-EXAMPLES-MIB::netSnmpExampleString='string'
Using the same input trap, the following configuration example formats the SNMP traps as JSON messages.
@include "scl.conf" log { source { snmptrap( filename("/var/log/snmptrapd.log") set-message-macro(no) ); }; destination { file("/var/log/example.log" template("$(format-json --scope dot-nv-pairs)\n")); }; };
The previous trap formatted as JSON:
{ "_snmp":{ "transport_info":"UDP: [127.0.0.1]:59993->[127.0.0.1]:162", "hostname":"localhost", "SNMPv2-SMI_snmpModules":{ "1":{ "1":{ "4":{ "1":{ "0":"NET-SNMP-EXAMPLES-MIB::netSnmpExampleHeartbeatNotification" } } } } }, "SNMPv2-SMI_mib-2":{ "1":{ "3":{ "0":"(666) 0:00:06.66" } } }, "NET-SNMP-EXAMPLES-MIB_netSnmpExampleString":"string", "NET-SNMP-EXAMPLES-MIB_netSnmpExampleHeartbeatRate":"60" } }
The snmptrap() driver has the following options. Only the filename() option is required, the others are optional.
Type: | path |
Default: |
Description: The log file of snmptrapd. The syslog-ng OSE application reads the traps from this file.
In addition to traps, the log of snmptrapd may contain other messages (for example, daemon start/stop information, debug logs) as well. Currently syslog-ng OSE discards these messages.
Description: This option makes it possible to execute external programs when the relevant driver is initialized or torn down. The hook-commands() can be used with all source and destination drivers with the exception of the usertty() and internal() drivers.
|
NOTE: The syslog-ng OSE application must be able to start and restart the external program, and have the necessary permissions to do so. For example, if your host is running AppArmor or SELinux, you might have to modify your AppArmor or SELinux configuration to enable syslog-ng OSE to execute external applications. |
To execute an external program when syslog-ng OSE starts or stops, use the following options:
startup() | |
Type: | string |
Default: | N/A |
Description: Defines the external program that is executed as syslog-ng OSE starts. |
shutdown() | |
Type: | string |
Default: | N/A |
Description: Defines the external program that is executed as syslog-ng OSE stops. |
To execute an external program when the syslog-ng OSE configuration is initiated or torn down, for example, on startup/shutdown or during a syslog-ng OSE reload, use the following options:
setup() | |
Type: | string |
Default: | N/A |
Description: Defines an external program that is executed when the syslog-ng OSE configuration is initiated, for example, on startup or during a syslog-ng OSE reload. |
teardown() | |
Type: | string |
Default: | N/A |
Description: Defines an external program that is executed when the syslog-ng OSE configuration is stopped or torn down, for example, on shutdown or during a syslog-ng OSE reload. |
In the following example, the hook-commands() is used with the network() driver and it opens an iptables port automatically as syslog-ng OSE is started/stopped.
The assumption in this example is that the LOGCHAIN chain is part of a larger ruleset that routes traffic to it. Whenever the syslog-ng OSE created rule is there, packets can flow, otherwise the port is closed.
source { network(transport(udp) hook-commands( startup("iptables -I LOGCHAIN 1 -p udp --dport 514 -j ACCEPT") shutdown("iptables -D LOGCHAIN 1") ) ); };
Type: | string |
Default: |
Description:If you receive the following error message during syslog-ng OSE startup, set the persist-name() option of the duplicate drivers:
Error checking the uniqueness of the persist names, please override it with persist-name option. Shutting down.
This error happens if you use identical drivers in multiple sources, for example, if you configure two file sources to read from the same file. In this case, set the persist-name() of the drivers to a custom string, for example, persist-name("example-persist-name1").
Synopsis: | prefix() |
Description: Insert a prefix before the name part of the parsed name-value pairs to help further processing. For example:
To insert the my-parsed-data. prefix, use the prefix(my-parsed-data.) option.
To refer to a particular data that has a prefix, use the prefix in the name of the macro, for example, ${my-parsed-data.name}.
If you forward the parsed messages using the IETF-syslog protocol, you can insert all the parsed data into the SDATA part of the message using the prefix(.SDATA.my-parsed-data.) option.
Names starting with a dot (for example, .example) are reserved for use by syslog-ng OSE. If you use such a macro name as the name of a parsed value, it will attempt to replace the original value of the macro (note that only soft macros can be overwritten, see Hard vs. soft macros for details). To avoid such problems, use a prefix when naming the parsed values, for example, prefix(my-parsed-data.)
Default value: .snmp. option.
Type: | yes|no |
Default: | yes |
Description: The snmptrap() source automatically parses the traps into name-value pairs, so you can handle the content of the trap as a structured message. Consequently, you might not even need the ${MESSAGE} part of the log message. If set-message-macro() is set to no, syslog-ng OSE leaves the ${MESSAGE} part empty. If set-message-macro() is set to yes, syslog-ng OSE generates a regular log message from the trap.